ADC Adtemp 415FL Instructions For Use Manual
AdtempTM415FLDigital Fever ThermometerInstructions for UseThank you for choosing an ADC ® AdtempTM digital stick thermometer. Your new thermometer isdesigned to provide accurate measurements. Adtemp thermometers meet or exceed all relevantinternational performance standards.Device Description and Intended UseThis device is intended to measure human body temperature in children and adults. It has acompact size and digital display and can be used in a professional or household environment.Parts and AssemblySymbol DefinitionsThe following symbols are associated with your thermometer.LIMITED WARRANTYADC warrants its products against defects in materials and workmanship under normal houshold use and service as follows:1. Warranty service extends to the original retail purchaser only and commences with the date of delivery.2. Your Adtemp Digital Stick Thermometer is warranted for two years from date of purchase.What Is Covered: Replacement of parts, and labor.What Is Not Covered: Transportation charges to ADC. Damages caused by abuse, misuse, accident, or negligence.Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, orconsequential damages, so this limitation may not apply to you.To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788.Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem.Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the originalselling price (except where prohibited by law). This warranty gives you specific legal rights and you may have other rights which varyfrom state to state.For Australian Consumers: Our goods come with guarantees that cannot be excluded under the Australian ConsumerLaw. You are entitled to a replacement or refund for a major failure and compensation for any other reasonable foreseeableloss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality andthe failure does not amount to a major failure.Visit www.adctoday.com to view this instruction booklet in other languages.Low-battery IndicationMemory IndicationMeasure ValueMeasure UnitProbe TipFlexible Probe TipDisplay WindowMultifunction ButtonSymbol DefinitionImportant warning/cautionNot made with natural rubber latexPhthalate freeOperating instructionsManufacturer’s informationAuthorized European representative’s informationLATEXSymbol DefinitionMeets essential requirements of EuropeanMedical Device Directive 93/42/EECLot numberMultifunction buttonAuto detection errorMemory indicationLow-battery indicationM0044SpecificationsSize 5.51”L x .78”W x 0.43”H (12.7 cm L x 1.9 cm W x .95 cm H)Weight 0.63 oz (18 grams)Display: LCD, Liquid Crystal DisplayBattery: 1.55V (LR41)Battery Life: Estimated 4,000 measurementsMeasurement Time: Oral 18-20 Seconds / Rectal 10 Seconds / Axillary 40 SecondsMeasurement Range: 90.0°F to 109.9°F / 32.0°C to 43.9°C (±0.2°F / ±0.1°C)Below 90.0°F (32.0°C) displays fixed “- - -” with fixed °F or °C.Above 109.9°F (43.9°C) displays flashing “H” with fixed °F or °Cand 10 times “Beep” sound.Accuracy: 0.2°F/0.1°C between 93.2°F to 107.6°F (34.0°C to 42.0°C)a room temperature of 64.4°F to 82.4°F (18°C to 28°C)±0.4°F/0.2°C between 90.0°F to 93.2°F (32.0°C to 34°C) and107.6°F to 109.9°F (42.0°C to 43.9°C)Operating Conditions: 50.0°F to 104.0°F (10.0°C to 40.0°C)Storage Conditions: -13°F to 131°F (-25°C to 55°C)Relative Humidity: 15-95% Non-CondensingMeasurement Mode: Real measurement with peak-hold methodAudible Alarm: 1 beep at start-up. Continuous beep at measurement completionAuto Turn Off: In approximately 8 minutesMemory Feature: Stores last temperature readingExpected Service Life: 5 yearsStandards: Complies with EN 12470-3, ASTM E 1112-00, IEC 60601-1,IEC 60601-1-2, IEC 60601-1-11, ISO 80601-2-56Electromagnetic compatibility: device fulfills the stipulations ofstandard IEC 60601-1-2The manufacturer recommends a calibration check every 2 years.IB p/n 93-415FL-00 rev 1 Printed in ChinaLATEXOnbo Electronic (Shenzhen) Co., Ltd.No. 497, Ta Laneg Nan Road, Ta Laneg StreetBaoan District, Shenzhen, ChinaMicrolife AG, Espenstrasse139, 9443 Widnau, SwitzerlandDist. by: ADC®55 Commerce Drive, Hauppauge, NY 11788Inspected in the USAMade in Chinatel: 631-273-9600toll free: 1-800-232-2670fax: 631-273-9659www.adctoday.comemail: info@adctoday.com0044EC REPRefer to user manual before use Type BF applied partBatteries and electronic devices must bedisposed of in accordance with the locallyapplicable regulations, not with domestic waste. |
Related manuals for ADC Adtemp 415FL
ADC Adtemp 413 Instructions For Use Manual
ADC Adtemp 412 Instructions For Use Manual
ADC Adtemp 413 Instructions For Use Manual
ADC Adtemp 418N Instructions For Use Manual
ADC Adtemp 433 Instructions For Use Manual
ADC Adtemp V 418N Instructions For Use Manual
ADC Adtempt 419 Instructions For Use Manual
ADC Adtemp ULTRA 417 Instructions For Use Manual
ADC Adtemp Mini 432 Instructions For Use Manual
ADC Adtemp 427 TempleTouch Instructions For Use Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine