– 67 –System Operation (cont’d)Description AlphaSystem Test (continued)Untyped Alarm Weak Battery U WEAK BATAccess2-Man 2 ND Person ACCESS 2NDKeypad Lockout KEYPD LOCKCardreader Irregular Access IRR ACCESSManual Pushbutton Access – remote arm/disarm opening MAP ACCESSAccess Denied Code Known – access denied DENIED NAAccess Denied Code Unknown – access denied INVALID NADialer TestDialer Test Report DLR TESTDialer Test Report with System Trouble Present TBL TESTBypassing/Unbypassing Burglary ProtectionBypassing a point or part of the burglary protection will cause the system toignore that point or portion of protection until it is unbypassed (restored tonormal operation) or the system is turned off.Bypassing may be required to ignore a malfunctioning device or to allowaccess to permanently secured areas. Only those users assigned the privilegelevel of "Can Bypass BA" may bypass and unbypass protection.Bypassing Protection PointsNote: A bypassed point cannot detect intrusion or an alarm condition.Before resorting to bypassing a point, attempt to repair or correct theproblem.1. Using the operating panel’s numeric keypad, enter a valid ID code thathas been assigned the privilege level of "Can bypass BA."2. Press More twice to display Action Menu 3.3. Press Bypass to display the Bypass Selection Menu 1.