Option Modules NetVanta 1224STR DC Hardware Installation Guide26 Copyright © 2013 ADTRAN, Inc. 61200590E1-34BNetVanta E1/FE1 + G.703 Drop NIM (P/N 1200878E1/L1)The NetVanta E1/FE1 + G.703 Drop NIM (see Figure 9) provides a single WAN-E1 interface (2.043 Mbps)with user-selectable TS0 assignment, and a G.703 drop port that may be used to drop and insert traffic to an E1PBX. See Table A-7 on page 45 for the WAN-E1 pinouts. See Table A-9 on page 46 for the G.703 pinouts. SeeTable A-13 on page 48 for the DBU connector pinouts. An optional DIM is required for dial backupapplications.Figure 9. NetVanta E1/FE1 + G.703 Drop NIMWAN-E1 G.703 DBUFeatures and SpecificationsOperating Modes• Frame Relay, Multilink Frame Relay• PPP, Multilink PPP• HDLCWAN-E1 Interface• Supported Standards: ITU G.703,ITU-T G.704 (CRC-4), ITU-T G.823,ITU-T G.797• Line Rate: 2.048 Mbps +50 PPM• Line Code: AMI or HDB3• Framing: FAS with optional CRC-4• FE1 Line Rate: Channelized timeslot (inmultiples of 64 kbps)• Receiver Sensitivity: -30 dB• Connector: RJ-48CG.703 Interface• Receiver Sensitivity: -30 dB• Line Rate: 2.048 Mbps +50 PPM• Line Code: AMI or HDB3• Framing: FAS with optional CRC-4• Capacity: 1 to 31 timeslots• Connector: RJ-48CClock Source• Network• Internal• ThroughDiagnostics• Test Pattern Generation and Detection:QRSS, 511, all ones, all zeros• Network loopbacks• Network performance data (15 minutesand 24 hours)• Alarm generation and detectionCompliance• EMC - see ElectromagneticCompatibility (EMC) Table on page 6 .• AS/ACIF S016• ETSI TBR 12/TBR 13• EN 60950• IEC 60950• AS/NZS 60950• RoHS Compliant (Telecommunicationsexemption)Environmental• Operating Temperature: 0°C to 50°C• Storage Temperature: -20°C to 70°C• Relative Humidity: Up to 95 percent,noncondensingPhysical• Dimensions: 2.75-inch W x 4.25-inch D