101. Depress and turn the control knobfor the burner, the left to Max. flame2. The ignition electrode will emitsparks, and when the mixture of gasand air is correct, the burner will beignited. Is not possible to connectthe unit to mains, a match may beused to ignite the burner3. After starting the burner, press thecontrol knob for approx. 10seconds to activate the automaticthermo couple.4. Important Ignition position is atMax flameIgnitionsGas installationThe appliance is factory set forNatural Gas. Fit the gas regulatorsupplied with the appliance to the gasinlet. The location of the gas inlet isapproximately 240mm form the righthand side of the appliance and40mm from the back of the appliance.The connection of the Gas Regulatoris ½” Gas female thread and thepressure at the test point should beadjusted to1.00kPa with the large andsimmer burners operating atmaximum.For Universal LPG connection, theappliance needs to be first convertedusing the conversion kit andinstructions supplied with theappliance.15Fixing* Prepare the cut out according tothe "cut out measurements”.Connect the brass extension Piece tothe bras elbow on the underside of hob.* Screw the fixing brackets out to suchan extent that they can be turned inunder the table top.Tighten the brackets on the to tabletop with an ordinary screwdriver.