14Installation InstructionsSafety instructions when building inThe laws, ordinances, directives and standards in force in the country ofuse are to be followed (safety regulations, proper recycling in accord-ance with the regulations, etc.)Installation may only be carried out by a qualified electrician.The minimum distances to other appliances and units are to be ob-served.A protective floor must be installed under the appliance.The cut surfaces of the worktop are to be protected against moistureusing a suitable sealant.The sealant seals the appliance to the work top with no gap.Ensure anti-shock protection through correct installation by a qualifiedelectrician.Safety instructions when connecting to the electric-ity supplyIf this appliance’s mains cable is damaged, it must be replaced by a spe-cial cable (type H05BB-F Tmax 90°; or higher). The latter is availablefrom the Customer Care Department.Observe electrical safety rules.A device must be provided in the electrical installation which allows theappliance to be disconnected from the mains at all poles with a contactopening width of at least 3 mmSuitable isolation devices include line protecting cut-outs, fuses (screwtype fuses are to be removed from the holder), earth leakage trips andcontactors.Safety instructions when connecting to the gas sup-ply1 Warning!When installing, the appliance must not be connected to the electricalsupply. Disconnect the mains plug or switch off or take out the fuses.Shut off mains gas supply.• A stop tap must be built-in between the house’s gas supply and theappliance.• Before connecting the appliance, check whether the local connectionconditions (type of gas and gas pressure) match the appliance’s set-up.