• Replace the damaged mains cable with a special cable (type H05BB-F Tmax 90°C; orhigher). Speak your local Service Force Centre.The appliance must have the electrical installation which lets you disconnect the appliancefrom the mains at all poles with a contact opening width of minimum 3 mm.You must have correct isolation devices: line protecting cut-outs, fuses (screw type fusesremoved from the holder), earth leakage trips and contactors.Sticking on the seal• Clean the worktop in the area of the cut-out section.• Bond the sealing tape to the lower edge of the cooking surface along the outer edge ofthe glass ceramic. Do not extend it. Let stay the cut ends in the middle of one side. Whenyou have cut it to length (add some mm), push the two ends together.Assemblymin. 500 mmmin.50 mmmin.50 mmmin.5 mm600mm380+1mm 880+1mm= =R 5mmInstallation 5