AX1 ICON User Manual17Version 1.0System Test Mode(A) Walk Test2. Press [TEST] key, then press [ ] to scroll to WALK Test and followed by [#] key to enterthe mode.3. Each time zone faulted, siren will sound for 2s and the corresponding zone light willfast flash with keypad buzzer beeping.4. To exit walk test, press [BACK] key.(B) Bell Test1. Bell test allow on-site testing for siren & bell functionality.2. Siren and bell will sound for 3 seconds.3. If siren or bell does not sound, consult your system installer.1. Walk test allow on-site testing for each zone of the system.(Press and hold for 2s)+ [ ] + [#](When [ ] is entered) (When [#] is entered) (Walk Test in progress)(Press and hold for 2s)+ [ ] + [#](2 times)(When [ ] is entered) (When [#] is entered)