bdi NDI JTAG debug interface for EDGE Debugger, BDI2000 (PPC4xx) User Manual 16© Copyright 1992-2008 by ABATRON AG V 1.064 BDI working modesdialog box «BDI Working Mode»With this dialog box you can define how the BDI interacts with the target system.Identification Enter a text to identify this setup. This text can be read by the debuggerwith the appropriate Command.Startup Startup mode defines how the BDI interacts with the target processor afterreset or power up. The options RESET, STOP or RUN can be selected.CPU Type Select the CPU type of the target system. For PPC440GX/EP/SP definean IR length of 8 via a special entry in the init list.JTAG Clock This option allows to select the used JTAG clock rate.Run Time When startup mode STOP is selected, this option allows to set the runtime after reset in milliseconds until the target CPU is stopped. Valuesfrom 100 (0.1 sec) till 32000 (32 sec) are accepted.Catch exceptions Check this switch if the BDI should catch unhandled exceptions. Catchingexceptions is only possible if the vector table is writable. The final EVPRvalue should be set with the initialization list because the BDI reads theEVPR to get the base address of the vector table.Transmit Click on this button to send the initialization list and the working mode tothe BDI. This is normally the last step done before the BDI can be usedwith the debugging system.