148 COMMISSIONING1 Check the free movement of the door.2 Turn mode switch to MAN. The mode switch is located in the head panel.3 Plug in the mains.4 Choose the type of thearm.5 Choose the size of the door.ARMstandardslidingJumpers are located on the control board.Jumper is connected.Jumper is disconnected.DOORsmallmediumlargesealedcustom S, M and L settings define door weight in ratio to door width. Always selectat first S in to guarantee maximum safety. If there is not enough force onthe operator for moving the door then shift setting from S to M. If the doorbehaviour is satisfactory then the chosen value is right. If not then shift to nextsetting point L.smallmediumlargesealedcustomDOOR”Sealed” enables motorised closing pull before opening and hold closed force.Select this to ensure the proper function of the lock when prepull is needed.smallmediumlargesealedcustomDOORJumper in block ”Custom” together with S, M or L gives you more power.S + Custom, force between S and M.M + Custom, force between M and L.L + Custom, force more than L.6 Check the PREPULL.0,5 s1,0 s1,5 sPush&GoPREPULLPREPULL0,5 s1,0 s1, 5 sPush&GoFor ”Sealed” it is possible to select different prepull times. By changing jumper, theprepull time changes for example from 0,5 to 1,0 second.Operator opens the door to adjusted opening angle and closes the door aftera 5 second of hold open time.TEACH CLOSEDTEACH OPENPOWER ON7 Teach door open and closed position.(is functional in program selector positions MAN and AUTO)TEACH- Push TEACH-button to enter learning mode.- Teach the door closed position:Yellow led blinks: close the door and push TEACH-button.- Teach the door open position:Green led blinks: open the door to the desired angle and push TEACH-button.- Yellow ”TEACH CLOSED” led blinks: close the door manually.