63 GENERAL INFORMATIONTechnical dataMeasures• 721 (L) x 85 (H) x 107 (W) mm• Weight 9 kg• Supply voltage 100/230 VAC (±10 %) 50...60 Hz• Rated output 120 W• Enclosure class IP20Temperature range• Storage -20...50 °C (in dry premises)• Operation -15...50 °C (in dry premises)• The automatic swing door operator must not be installed in applications where it is subjected to water orsnowInterfaces• Voltage output 24 VDC, stabilized, 500 mA (max 800 mA for 3 seconds)• Potential free relay output0,8 A @ 30VDC resistive load0,3 A @ 30VDC inductive loadDoor closer according EN1154:Features• Easy to install• Normal door closer function when the power is switched off or templed• Push&Go as a standard feature• Prepull before opening• Adjustable hold open time 0...60 s or sequential use• Fire detector connection• Lock control relay with NO/NC contacts• Secondary DC inlet for power back up (24 VDC (±15 %), min. 5A)• Maximum opening angles:With standard arm 110°With sliding arm (on the opening side) 100°With sliding arm (on the closing side) 100°Class Standard arm Sliding arm Closing torqueDoor mass [kg]/ width [mm]Door mass [kg]/ width [mm][Nm](0-4°)1 20 / 750 92 40 / 850 133 60 / 950 60 / 950 184 80 / 1100 80 / 1100 265 100 / 1250 376 120 / 1400 54