5514.7 WAM outputsThe WAM wireless outputs can be edited after training the WAM as a wirelesstransmitter or receiver (function 3).Select output 31 using the arrow keys (WAM 1).Edit the menu point under output 31.Select the Name menu item.Assign a new name and finish data entry by pressing OK.Select the Type menu item.An overview of output types can be found in the following table.Type MeaningNot Used This output is not in use and is never activated. (Exception:complete power loss).Local This output is activated on local alarms for the defined sirenduration.E/E Follow This output is activated for the duration of the delay time(entry/exit delay active).Armed Lamp This output is activated as long as the alarm centre isinternally or externally activated.24 Hour This output is activated if a 24-hour zone triggers an alarm.Strobe This output is activated for a local alarm and remains activeuntil the wireless alarm centre is deactivated.Strobe Set This output is activated for approx. 10 seconds followingsuccessful activation of the wireless alarm centre and is usedfor acknowledging activation. The function must also beactivated in the partition menu. This output is also activatedfor a local alarm and remains active until the wireless alarmcentre is deactivated.Pulse Set This output is activated for approx. 1 second followingsuccessful activation of the wireless alarm centre.Pulse Unset This output is activated for approx. 1 second followingsuccessful deactivation of the wireless alarm centre as well asfor a panic or fire alarm.Setting Complete This output is activated for approx. 10 seconds followingPlease note that the disconnected WAM outputs have a maximum loadof 500 mA at 24 V. This is an opto-isolator with a forward resistance of2 Ω.WAM 1 output 1 Secvest output 31In the installer menu:Æ ÆSelect the Edit Output menu item.