14English3.2. ResetTo reset the camera to its factory settings, first disconnect the power supply. Keep the reset buttonpressed and reconnect the power supply to the camera. Continue pressing the reset button for another15 seconds, then release.NoteOn some cameras, the same button is used for the reset function and the WPS function.Please refer to the description of the camera.3.3. WPSTo use the WPS function via the hardware button, connect the camera to the power supply. Waitapproximately one minute until the camera has fully started up. Then, first enable the WPS function onyour receiver (router or recorder). Next, press and hold down the WPS button on the camera for 15seconds.NoteOn some cameras, the same button is used for the reset function and the WPS function.Please refer to the description of the camera.3.4. Alarm input/outputThe alarm inputs/outputs are identified as follows on the cameras: I = Input O = Output G = Earth (ground)The connections are potential-free relays which can be operated with the following maximumconnection voltages: Max. 120 VAC / 1A Max. 24 VDC / 1AConnect your peripherals as follows: Sensor:Connect your sensor to the output and earth. Actuator:Connect your actuator to the output and earth.Note for TVIP11561The earth can be used simultaneously for a sensor (input + earth) and an actuator (output+ earth).