94MS41 Rev. C1 S/W Ver 2.06 11-5[0096] Press the 6 key again: upper tray should move in, the Vacuum windowshould read [0096].• Set volt meter for VDC and measure across pins 5 & 6 on motor speedconnector. Adjust the 'SLOW' pot on the control box to read 25 to 32VDC. Notice that the frame moves slower than normal. The total traveltime of the frame should be 12 seconds.VACUUMPUMPSACCESSORYA/CCOMMUNICATIONLINE VOLTAGESELECTIONSWITCHHF1 BLOWERPOWER SUPPLY HF1 BLOWER POWER SUPPLYMOTORL - SWTSTOPINSLOWOUTFASTMOTOR SPEEDSLOW12 VDC• Exit the diagnostic mode by pressing the 9 key then the 0 key.Adjust the 'FAST' pot on the control box.• Depress and hold the 'STOP' key then press the 'GO' key and then releaseboth keys to start a blank frame cycle, no vacuum or exposure.• Measure across pins 5 & 6 on motor speed connector. Adjust the 'FAST'pot on the control box to read between 70 and 84 VDC. The frame shouldtravel at high speed for about 4.5 seconds, then shift to a slower speedand stop about 0.750" to 1" from the end of the tray rod.! C Verify the adjustment by noting the position of the frame whenit is inside the Unit. Check the frame position switches foreach frame. When adjusted properly, the frame will come toa stop depressing the first switch, but not the second. If thesecond switch is depressed, check slow speed adjustment.