Accurate Technology Digi-Stop Page 15 of 20Readout ProgrammingSeveral functions of the Digi-Stop Readout are user programmable. Thefollowing describes what features and functions are available and how tochange the factory defaults to customize your Digi-Fence system..Review KEY TIMING described earlier before proceeding.To enter Programming Mode:1. Press and hold the UNITS key then momentarily press the DATUM key.2. The LCD will briefly display: PG on (Programming On), thenPr 1, (indicating Programming Parameter #1)3. Release the UNITS key4. The value stored in Pr1 is displayed.Once in the Programming Mode:Moving up parameter list - Momentarily press the UNITS key to advance throughthe Programming Parameter list, first displaying the Programming Parameternumber then the currently programmed value.Moving down parameter list - Press and hold the ON/OFF key and momentarilypress the UNITS key to move backward through the Programming list.Increase parameter value - Momentarily press the PLUS (+) key while displayinga Programming Parameter Value to increase the setting.Decrease parameter value - Momentarily press the MINUS (-) key whiledisplaying a Programming Parameter Value to decrease the setting.Reset parameter value to default setting - Momentarily press the DATUM keywhile displaying a Programming Parameter Value to reset the parameter to thefactory default value.Exit programming mode - Press and hold the UNITS key. Momentarily depressthe DATUM key. The LCD will briefly display: PG oFF (Programming Off),then return to normal operation. NOTE: The system will automatically exitprogramming mode after 60 seconds if no key activity is detected.Momentarily pressPress & Hold