Appendix C: SCSI RAID configuration160If you change the settings in the Hot Spare field, the followingmessages appear:WARNING: Data on drive will be LOST!Press DELETE if data loss OK or any other key tocancel.6 Press the Delete key to ignore.7 Press Esc, then select Save changes then exit this menu.8 To close the utility and reboot the server, follow the steps below:(1) Press Esc, then select Exit the Configuration Utility.The Global properties saved. Hit any key toreboot message appears.(2) Press any key to reboot the server.RAID volume initializationAfter you create the RAID volume and saved the changes, the diskcontroller will automatically initialize the RAID volume. LSI Logic53C1030 supports background initialization, there’s no need to waitfor the initialization to complete. Close the LSI Logic ConfigurationUtility after saving the changes.Using the MegaRAID configuration utilityTurn on the system. When prompted, press Ctrl+M to enter theMegaRAID configuration utility. After a few seconds, the Managementmenu appears.Loading the RAID card default setting1 In the Management menu, select Objects, then select Adapter.The current adapter settings appear.2 Select Factory Default, then Yes to load the default settings.3 Press Ctrl+Alt+Del to reboot the server.