Chapter 1 25Regulatory Requirements Safety Requirements:1.The subject product rated 100-120V 60Hz must be listed under UL 1950 andcertified with SCA Standard C22.2 No.950.2.The subject product rated 200-240V 50Hz must comply with low voltagedirective 73/23EEC.EMI Requirements:1.The subject product rated 100-120V 60Hz must meet the EMI requirementsof FCC part 15, Subpart B for Class B Digital Device and get FCC Certificationbefore marketing into USA and Canada.2.The subject product rated 200-240V 50Hz must meet the EMC Directive 89/336/EEC.3.The subject product rated 100-120V must meet the VCCI-2 EMIrequirements.Power ManagementPower Saving Mode PhenomenonStandby ModeEnter Standby Mode when1.Standby/Hibernation hot-key is pressedand system is not ready to enter Hibernationmode.2.System standby/ Hibernation timer expiresand system is not ready to enter Hibernationmode.T The buzzer beepsT The Sleep indicator lights upHibernation ModeEnter Hibernation Mode (suspend to HDD)when1.Hibernation hot-key is pressed andsystem is ready to enter Hibernation mode2.System Hibernation timer expires andsystem is ready to enter Hibernation mode.T All power shuts offDisplay Standby ModeKeyboard, built-in touchpad, and an externalPS/2 pointing device are idle for a specifiedperiod.T The display shuts offHard Disk Standby ModeHard disk is idle within a specified period oftime.T Hard disk drive is in standby mode.(spindle turned-off)Environmental RequirementsItem SpecificationTemperatureOperating +5~+35 °CNon-operating -20~+65 ° CPackage storage -20~+65 ° CHumidityOperating 20% to 80% RH, non-condensingNon-operating 10% to 90% RH, non-condensing (Unpacked)Non-operating 10% to 90% RH, non-condensing (Storage package)VibrationAC AdapterItem Specification