Chapter 4 91If any of these devices do not work, reconnect the cable connector and repeat the failing operation.Memory CheckMemory errors might stop system operations, show error messages on the screen, or hang the system.1. Boot from the diagnostics diskette and start the diagnostic program (please refer to main board.2. Go to the diagnostic memory in the test items.3. Press F2 in the test items.4. Follow the instructions in the message window.NOTE: Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error.Power System CheckTo verify the symptom of the problem, power on the computer using each of the following power sources:1. Remove the battery pack.2. Connect the power adapter and check that power is supplied.3. Disconnect the power adapter and install the charged battery pack; then check that power is supplied bythe battery pack.If you suspect a power problem, see the appropriate power supply check in the following list:• “Check the Power Adapter” on page 91• “Check the Battery Pack” on page 92Check the Power AdapterUnplug the power adapter cable from the computer and measure the output voltage at the plug of the poweradapter cable. See the following figure1. If the voltage is not correct, replace the power adapter.2. If the voltage is within the range, do the following:• Replace the System board.• If the problem is not corrected, see “Undetermined Problems” on page 104.• If the voltage is not correct, go to the next step.NOTE: An audible noise from the power adapter does not always indicate a defect.3. If the power-on indicator does not light up, check the power cord of the power adapter for correctcontinuity and installation.4. If the operational charge does not work, see “Check the Battery Pack” on page 92.Pin 1: +19 to +20.5VPin 2: 0V, Ground