A - 16 ES300 ST, ES300 XP, ES400 XLP - 56091171 9/2015INSTRUCTIONS FOR USEA - ENGLISHTROUBLESHOOTINGIf the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Advance Service Centerimmediately for service.TRIPPING THE CIRCUIT BREAKERThe Circuit Breaker (26) is located on the Control Panel; it protects the electrical circuit and brush motor from damage due to overload conditions. Ifthe circuit breaker is tripped try to determine the cause.Brush Circuit Breaker (5 Amp) Possible cause may be:1 Debris wrapped around the brush drive (remove debris)2 Electrical short circuit (have your Advance Service Center or qualified electrician check the machine)Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. Ifthe circuit breaker trips repeatedly, call your Advance Service Center for service.POOR WATER PICKUPPossible causes may be:1 Vacuum Mode Selector Knob (3) is set to the wrong mode or not properly seated (rotate knob fully to align with arrow icon)2 Recovery Tank Full (empty recovery tank)3 Function Selector Knob (25) is in Pre-Spray (25c) or Wand/Accessory Mode (25d) in which the vacuum motor is off (turn knob to one of theextraction positions (25a or 25b)4 Open recovery tank drain hose (secure drain hose cap or replace)5 Recovery hose not connected at vacuum shoe (connect hose to vacuum shoe)6 Recovery hoses not connected to the correct ports in the dome lid (connect hoses to correct ports)7 Recovery hose is kinked or damaged (replace the hose)8 Debris caught in vacuum shoe, mode selector paddle or recovery hose (clean vacuum shoe, mode selector and recovery hose)9 Recovery tank dome lid gasket leak (replace gasket)10 Seal on mode selector paddle is worn or missing (replace seal)INADEQUATE SOLUTION FLOWPossible causes may be:1 Solution tank empty (fill solution tank)2 Solution lines or solution filter clogged (flush lines and filter)3 Solution line not connected to filter assembly (connect solution line)4 Spray nozzle is plugged (clean spray nozzle)FUNCTION SELECTOR KNOB MATRIX (ES300 XP & ES400 XLP)The following matrix shows which functions are active “X” for each position of Function Selector Knob (25). This can be useful for troubleshooting.Position (25a) Position (25b) Position (25c) Position (25d) Machine FunctionX X X VacuumX X Solution (Restore Nozzle)X Solution (Maintenance Nozzle)X X X Brush