Management and configuration AXIS 570/670 User’s Guide32Test ButtonAll Axis print servers are equipped with a test button. The functionality of the test button isdetermined by the number of times the button is being pressed.• Press the test button once to print a test page that contains basic information about the AXIS570/670.• Double-click the test button to print out the current parameter settings of the unit.You can also reset the AXIS 570/670 parameters to their factory default settings by using the testbutton. Follow the instructions below:1. Remove the external power supply to switch off the AXIS 570/670.2. Press and hold down the test button, while you reconnect the external power supply. Continueto hold down the test button until the network indicator starts to flash at one second intervals.This should take about 5 seconds.3. Release the test button and wait until the network indicator flashes at least five times.4. Press and hold down the test button again until the network indicator remains constantly lit.5. Restart the AXIS 570/670 by switching it off and on.Note:All parameters except the node address (NODE_ADDR) and the IP address (IP_ADDR) are reset.Windows IBM Mainframe IBM AS/400UNIX NetWareOS/2Macintosh