AXIS M30 Network Camera SeriesAdditional settings2. Connect the power wire to pin 2 (12V DC output).3. Connect the I/O wire to pin 3 (I/O input).Connect the wires to the PIR detector’s I/O connector1. Connect the other end of the ground wire to pin 1 (GND/-).2. Connect the other end of the power wire to pin 2 (DC input/+).3. Connect the other end of the I/O wire to pin 3 (I/O output).Configure the I/O port in the camera’s webpage1. Go to Settings > System > I/O ports.2. Give the input module a descriptive name.3. To make the PIR detector send a signal to the camera when it senses motion, select Closed circuit in the drop-down list.To trigger the camera to start recording when it receives a signal from the PIR detector, you need to create a rule in the camera’swebpage.Detect tampering with input signalThis example explains how to trigger an alarm when the input signal has been cut or short-circuited. For more information about theI/O connector, see page 27.To watch this video, go to the web version of this document.www.axis.com/products/online-manual/34428#t10110432How to send an email notification when someone tampers with the input signal1. Go to Settings > System > I/O Ports and turn on Supervised I/O.Create a rule:1. Go to Settings > System > Events and add a rule.2. Type a name for the rule.3. In the list of conditions, select Digital input and then select a port.4. In the list of actions, select Send notification to email and then select a recipient from the list. Go to Recipientsto create a new recipient.19