AXIS M3024–LVE Network CameraDetectorsNote• Using the motion detection feature may decrease the product’s overall performance.• The position of the Motion Detection Window is relative to the orientation of the Camera. Changing the orientation of thecamera will also change the position of the Motion Detection Window.Set Up Motion Detection WindowsTo set up a motion detection Include Window, follow these instructions:1. Go to Detectors > Motion Detection.2. Select the Configure Included Windows option and click New. Select the new window in the list of windows andenter a descriptive name.3. Adjust the size (drag the bottom right-hand corner) and the position (click on the text at the top and drag to the desiredposition) of the window.4. Adjust the Object Size, History and Sensitivity profile sliders (see Motion Detection Parameters for details). Any detectedmotion within an active window is indicated by red peaks in the Activity window.5. Click Save.To exclude parts of the include window, select the Configure Excluded Windows and position the exclude window within theinclude window.To delete an include or exclude window, select the window in the list of windows and click Del.Motion Detection ParametersThe parameters controlling motion detection are described in the table below:Parameter Object Size History SensitivityDescription Object size relative to windowsize.Object memory length. Difference in luminancebetween background andobject.High level (100%) Only very large objects triggermotion detection.An object that appears inthe window triggers motiondetection for a long timebefore it is considered asnon-moving.Ordinary colored objects onordinary backgrounds triggermotion detection.Medium level (50%) A large difference in luminanceis required to trigger motiondetection.Low level (0%) Even very small objects triggermotion detection.An object that appears inthe window triggers motiondetection only for a very shorttime before it is considered asnon-moving.Only very bright objects ona dark background triggermotion detection.Recommended values 5–15% 60–90% 75–95%Default values 15% 90% 90%28