AXIS P1353–E Network CameraEvents- Day/Night Mode – Trigger the rule when the product switches between day mode (IR cut filter on) and nightmode (IR cut filter off). This can for example be used to control an external infrared (IR) light connectedto an output port.- Live Stream Accessed – Trigger the rule when any stream is accessed and during edge storage playback.This can for example be used to send notifications.- Motion Detection – Trigger the rule when motion is detected. See Motion Detection on page 35.- Tampering – Trigger the rule when tampering is detected. See Camera Tampering on page 35.• Hardware- Network – Trigger the rule if network connection is lost or restored. This can for example be used to startrecording to the SD card.- Temperature – Trigger the rule if the temperature falls outside or inside the operating range of the product. Thiscan for example be used to send maintenance notifications.• Input Signal- Digital Input Port – Trigger the rule when an I/O port receives a signal from a connected device. See I/OPorts on page 59.- Manual Trigger – Trigger the rule using the Manual Trigger button in the Live View page. See Controls onthe Live View Page on page 13. This can for example be used to validate actions during product installationand configuration.- Virtual Inputs – can be used by a VMS (Video Management System) to trigger actions. Virtual inputs can, forexample, be connected to buttons in the VMS user interface.• PTZ- Moving – Trigger the rule when the camera view moves due to a PTZ operation. This can for example be usedas an additional condition to prevent an action rule triggered by motion detection to record video while thecamera view moves due to a PTZ operation.- Preset Reached – Trigger the rule when the camera stops at a preset position. This can be for example be usedwith the Send Images action to upload images from the preset position.• Storage- Disruption – Trigger the rule if storage problems are detected, for example if the storage device is unavailable,removed, full, locked or if other read or write problems occur. This can for example be used to send maintenancenotifications.- Recording – Triggers the rule when the Axis product records to the storage device. The recording status triggercan be used to notify the operator, for example by flashing LED lights, if the product has started or stopped torecord to the storage device. Note that, this trigger can be used only for edge storage recording status.• System- System Ready – Trigger the rule when the product has been started and all services are running. This can forexample be used to send a notification when the product restarts.• Time- Recurrence – Trigger the rule periodically. See Set Up Recurrences on page 44. This can for example be used toupload an image every 5 minutes.- Use Schedule – Trigger the rule according to the selected schedule. See Create Schedules on page 43.41