AXIS P33/P33-V Network Camera Series Installation Guide Page 21ENGLISHResetting to the Factory Default SettingsThis will reset all parameters, including the IP address, to the factory default settings:1. Disconnect power from the camera.2. Press and hold the Control button and reconnect power (see Hardware overview, on page 6).3. Keep the Control button pressed for about 15 seconds until the Status indicator flashes amber.4. Release the Control button. The process is complete after about 1 minute (when the Statusindicator turns green). The network camera has been reset to the factory default settings. Thedefault IP address is 192.168.0.905. Re-assign the IP address.6. Refocus the camera.It is also possible to reset parameters to factory default via the web interface. Go to Setup > SystemOptions > Maintenance.Accessing the camera from the InternetOnce installed, your network camera is accessible on your local network (LAN). To access thecamera from the Internet, network routers must be configured to allow incoming traffic, which isusually done on a specific port• HTTP port (default port 80) for viewing and configuration• RTSP port (default port 554) for viewing H.264 video streamsPlease refer to the documentation for your router for further instructions. For more information onthis and other topics, visit the Axis Support Web at www.axis.com/techsupFurther informationThe user’s manual is available from the Axis Web site at www.axis.com or from the Axis NetworkVideo Product CD supplied with this product.Tip!Visit www.axis.com/techsup to check if there is updated firmware available for your Axis product.To see the currently installed firmware version, see Setup > About in your web interface.