AXIS Q7900 Installation Guide Page 5ENGLISHAXIS Q7900 Rack (FrontView)Install the hardwareGeneral placement requirementsThe location of the AXIS Q7900 must meet the following requirements:• Ambient temperature: 0° to +45°C (32° to 113°F)• Relative humidity: 20-80%• Power source within 1.8 meters• There must be a minimum of 5cm free space on the top, bottom, front and rear of the AXISQ7900 to ensure adequate ventilation• No excessive dustPlacement requirements for installation in a 19” equipment rackWhen mounting the AXIS Q7900 in an equipment rack, never stack other units directly on top - themounting brackets are not designed to support more than 1 unit.• Pozidriv screwdriver #1• Pozidriv screwdriver #3• The AXIS Q7900 must be grounded to the same ground as the equipment rack.• The equipment rack must be braced and bolted to the floor.AXIS Q7900 RackACTIVITYLOOPNETWORK1 2 3 4PS1PS 2FANSPOWE R123456POWE R123456POWER123456POWER123456POWE R123456POWE R123456POWE R123456POWE R123456POWE R123456POWE R123456POWE R123456POWE R123456POWE R123456POWER123456Power supply 2Network Activity &Loop LEDs 1-4AXIS VideoEncoder BladesSlot 1 Slot 14Power supply 1PS 1-2 &Fan LEDsFans button