AXIS T8341 PIR Motion SensorZ-Wave configurationZ-Wave configurationThe following information is for someone that has some experience in setting up a Z-Wave system, or someone that has computersoftware running a Z-Wave controller. Please get familiar with the software of the Z-Wave controller before getting started.To minimize power consumption of the battery, RF on the device is switched off as default. In order to start the set up process, pleasepress the tamper switch once to turn on the RF power for 30 seconds. You can then see the LED start to blink every second. If set upis not finished within 30 seconds, please press the tamper switch one more time to continue the set up• Basic set levelWhen a Basic Set Command is sent and contains a value, the receiver will process it. For example, a lamp module wouldreceive a Basic Set command which determines the dim level.Example:1-99: ON (Binary Switch Device)Dim Level (Multilevel Switch Device)Function Parameter number Size Range DefaultBasic Set level 1 1 1~99 99• Sensitivity level (PIR sensor only)For optimal efficiency, it is recommended to test the detector’s response to movements from the farthest end of thecoverage area when you use it for the first time. If movements cannot be detected accurately, simply adjust the sensitivitylevel with the Configuration Parameter #3. This parameter can be configured with a value from 1 to 10, where 1 meanslow sensitivity and 10 means highest sensitivity.Function Parameter number Size Range DefaultSensitivity level 3 1 1~10 6• Re-trigger interval setting (PIR sensor only)The configuration parameter used to adjust the re-trigger interval after the detector has been triggered as configurationparameter #4. No response will be made during this interval if a movement is detected. The time interval can be setbetween 5 seconds to 3,600 seconds.Function Parameter number Size Range DefaultRetrigger interval 4 2 5~3600(sec) 180• Lux levelYou can set a percentage for the lux level which determines when the light sensor will be activated. If the ambientillumination drops below the set percentage, and a person moves across or within the protected area, the detector willemit a Z-Wave ON command (i.e. Basic Set command (Value = Basic Set Level)) to the controller and activate connectedmodules and lighting. The percentage can be set between 1% to 100%.Function Parameter number Size Range DefaultLux level 5 1 1~100% 20On-off durationThe on-off duration setting can be useful if the detector is connected to a module or lighting. The duration determines how long themodule/lighting should stay ON. For instance, a Lamp Module turns off 100 secs after it has been turned on. The duration can beconfigured to last between 5 to 3600 seconds.10