AXIS T8342 Door/Window SensorHow to program the Z-Wave device• COMMAND_CLASS_WAKE_UP_V2• COMMAND_CLASS_NOTIFICATION_V4Wake up command classAfter the detector has been included into a Z-Wave network it will go to sleep, but it will send a wake-up notification command tothe controller periodically at a preset period . The detector will stay awake for at least 10 seconds and then go back to sleep toconserve battery life.The time interval between wake up notification commands can be set in the wake up command class based on the range values below:Minimum wake up interval 600s (10 minutes)Maximum wake up interval 86400s (1 day)Default wake up interval 14400s (4 hours)Wake up interval step seconds 600s (10 minutes)9