INDICATOR-LABELLER BLP-5453 41∗∗∗∗ F 0 7 9 0∗∗∗∗∗∗∗∗∗∗∗∗ F 0 0 0 0X....Prog.Format Date 0Prog.LIST- - - -6.8 PROGRAMMING DATE FORMAT ONLABELSPress the sequence ∗∗∗∗ F 0 7 9 0 to enter programmingPress PLU 8HEnter the date format in accordance with this table:Number Format Example0 Ddmmyy 28.02.021 DdMONTHLETTER.yy28.FEB.022 Ddmmyy 28.02.20023 DdMONTHLETTER.yyyy28.FEB.20024 Dd/mm/yy 28/02/025 Dd/MONTHLETTER/yy28/FEB/026 Dd/mm/yyyy 28/02/20027 Dd/MONTHLETTER/yyyy28/FEB/20028 Mm.dd.yy 02.28.029 MON LETTER.dd.yy FEB.28.0210 Mmddyy 02.28.200211 MONLETTER.dd.yyyy FEB.28.200212 Mm/dd/yy 02/28/0213 MON LETTER/dd/yy FEB/28/0214 Mm/dd/yyyy 02/28/200215 MONLETTER/dd/yyyyFEB/28/200216 Dd COMPLETE MONLETTER yyyy28FEBRUARY200217 COMPLETEMONTHLETTER dd yyyyFEBRUARY28 200218 Ddmmyy 28020219 Mmddyy 022802Press ∗∗∗∗ to accept the date format selected and once againto quit.Irrespective of the date format, the date is alwaysprogrammed in the dd-mm-year order.Programming affects the order and way in which the datefields are printed, not the programming of the clock.6.9 ACCESS CODE TO LISTSThe access code to lists can be changed. It is done asfollows:1. Press the ∗∗∗∗ and F keys and the old access code to lists(by default 0 0 0 0).2. Press X and enter 4 numbers as the new access codeto lists.If you have forgotten the old access code contactyour supplier or Technical Assistance of yourlabelling machine.