Bajaj Storage Water Heater User Manual
bajaj electricals limited Page 3 of 8This device gives protection against both high and low pressures and is the safest method of installation.This device also enables the following:1. Provision of an extra fusible plug at the top.2. Provision for accessories like Dead Weight Valve, vacuum relief valve etc.3. Non-pressure type installation.NON-RETURN DEVICE: There is a siphon hole on the inlet pipe inside the inner tanks of all Bajaj Storage WaterHeaters. When pressure inside the tank becomes low, this siphon hole prevents back flow of water. It acts as a nonreturn device up to a certain level of low pressure. Thus it prevents collapse of the tank due to vacuum formation.BENEFITS1. A two-year guarantee.2. Attractive colours in two-tone powder-coated finish.3. Suitable for multi-point usage (pressure type) and single point usage.4. The largest dealer and After Sales Network available in the country.5. Rust proof Stainless Steel Hardware facilitates easy servicing.THE HOW AND WHERE OF INSTALLATION AND OPERATIONA. Fix the Water heater in a perfectly straight position at a suitable height from the floor. While fixing thehorizontal wall models the inlet and the outlet pipes should be on the right side of the person fixing it.B. There should be enough space around the heater for easy installation and servicing.C. Make sure that supporting walls or fixture are strong enough to carry the weight of the heater when it iscompletely filled with water.D. A typical installation (for vertical and horizontal mountings) is shown in Fig.2, 3, 4 & 5. For overall and mounting dimensions please refer the technicalspecifications table.E. There should be a minimum space of 50 cm between the top of the heaterand the roof. This is to make sure that the heater can be removed andtaken out when necessary.F. The heater should be saved from being damaged by splashing of water.Therefore, keep a minimum space of about 1.8 m. between the floor andbottom of the heater.G. When the mounting is horizontal, keep a minimum space of 50 cm betweenthe wall and inlet/outlet pipes so that parts can be easily removed forservicing etc.H. INSTALL A VRV (VACUUM RELIEF VALVE) IN CASE THE WATER HEATER ISINSTALLED IN MULTI STOREYED BUILDING.WATER SUPPLY:A. You can connect the heater directly to municipal water supply or the watertank on top of your house. But take care that the distance between theheater unit and the tank is not more than 70 feet. This is equivalent to 30P.S.I. or 2.1 Kg/cm2 pressure.B. If the height is more, use a Pressure reducing valve at the inlet.C. The water pressure should also not be too low. The minimum distancebetween the heater and the water supply tank should be at least 2 metres.D. WHEREVER POSSIBLE YOU SHOULD INSTALL THE VENT PIPE FROM THETOP OF THE HEATER UP TO THE LEVEL OF THE WATER SUPPLY TANK. THERE, IT SHOULD BE LEFT OPEN TOTHE ATMOSPHERE. THIS IS THE SAFEST METHOD OF INSTALLATION. |
Related manuals for Bajaj EE 10
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine