(4) Position 'Rack Supports' and tighten in place using 4 each of Flat washers and 5/16-18 Hex Nuts.(1 ) Tilt cabinet over onto the left hand side. Attach two mounting plates to the right underside and screw6" legs into the center holes.(2) Lift up left hand side of the base cabinet and attach the mounting plates and 6" Iegs on theunderside and screw 6" legs into center holes.(3) Using the lifting equipment, raise the top oven to proper height and slide on top of the base cabinet.Line up sides and front and fasten to each other with stacking brackets.Four casters (two with wheel brakes) and the mounting hardware are packed and included in the shipmentif ordered.Install casters with wheel brakes on the front of the unit.Installation of the unit should be made with a connector that complies with the latest edition of the Standardfor Connectors for Movable Gas Appliances ANSI Z21.69, in the USA (CAN CGA-6.16 in Canada) and aquick disconnect device that complies with the latest edition of the standard for quick disconnect devicesfor use with gas fuel ANSI Z21A I in the USA (CAN 1-6.7 in Canada.) Adequate means must be provided tolimit the movement of the appliance without depending on the connector and any quick disconnect deviceor its associated piping to limit the appliance movement.The restraint should be attached to the rear legs of the oven on which casters are mounted. If disconnectionof the restraint is necessary, the restraint should be reconnected after the appliance has been returned toits originally installed position.Move the oven to its final location keeping the minimum clearance from the back of the oven to the wall. Thisclearance is necessary for safe operation and to provide proper air flow to the burner chamber.Under Ventilation Direct VentingRIGHT WALL 1” 1"LEFT WALL 1" 3"REAR WALL 3" 3"To assemble over a Base Cabinet:C. INSTALLATION WITH CASTERS (OPTIONAL):D. LOCATION AND MINIMUM CLEARANCES:HoodMINIMUM CLEARANCES FROM COMBUSTIBLE AND NON-COMBUSTIBLE CONSTRUCTIONqSUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR WHEN INSTALLED WITH LEGSOR CASTERS PROVIDED.CAUTION: DO NOT SET THE OVEN WITH ITS BACK FLAT AGAINST THE WALL. IT WILL NOTOPERATE PROPERLY UNLESS THERE IS AT LEAST THREE INCHES BREATHING SPACEBEHIND THE OVEN.E. GAS CONNECTIONS:The ovens should not be installed on the same gas line with space heaters, boilers or other gas equipmentwith high intermittent demand.The installation of this oven must conform with the latest local codes orThe appliance must be isolated from the gas supply piping system by closing it’s manual shut-otf valveduring any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi(3.45kPa). The appliance and its shut-off valve must be disconnected from the gas supply piping systemduring any pressure testing of that system at test pressures in excess of ½ psig (3.45kPa).Nationa/Fuel Gas Code. ANSIZ223.1, Natural Gas Installation Code. CAN/CGA-BJ49.1. or the Propane Installation Code. CAN/CGA-BJ49.24