151.5 General Performance SpecificationsTable 1-5 outlines the general performance specifications of the BC140 / BC140-FBR control.Table 1-5 General Performance Specifications1Description Specification FactorySettingSpeed Range (Ratio) 50:1 —Armature Feedback Load Regulation (0 - Full Load, 50:1 Speed Range) (%Base Speed) 12 —Line Voltage Regulation (at Full Load, ± 10% Line Variation) (% Base Speed) 0.52 —Control Linearity (% Speed vs. Dial Rotation) 2 —Acceleration (ACCEL) Trimpot Range (Seconds) 0.2 - 10 2Deceleration (DECEL) Trimpot Range (Seconds) 0.2 - 10 2Maximum Speed (MAX) Trimpot Range (% Base Speed) 50 - 1102 100Minimum Speed (MIN) Trimpot Range (% Base Speed) 0 - 302 0CL/Torque Range (% Full Load) 0 - 200 150IR Compensation (IR) Trimpot Range (at Specified Full Load at 90/180 VoltsOutput) (Volts DC) 0 - 24 / 0 - 48 3 / 6Operating Temperature Range without Optional Auxiliary Heat Sink (CatalogNo. BC143) (°C / °F) 0 - 40 / 32 - 104 —Operating Temperature Range with Optional Auxiliary Heat Sink (Catalog No.BC143) (°C / °F) 0 - 50 / 32 - 122 —Notes:1. CE Compliance requires BC24-LF RFI Filter. (See Optional Accessories, Table 1-2).2. Performance is for 90 Volt PM motors with 115 Volt AC line input and 180 Volt DC PM motors with 230Volt AC line input.