Emergency Stop Safety ModuleModel ES-GA-5A for 24V dc/115V ac operation; Model ES-HA-5A for 24V dc /230V ac operationWARNING . . . This Emergency Stop Safety Module is not a point-of-operation guarding device, asdefined by OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safetylight curtains and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-of-operation guards on hazardous machinery can result in a dangerous condition which could lead to seriousinjury or death.!• Monitors one dual-channel normally-closed emergency stop switch circuit for acontact failure or wiring fault• Input monitoring circuit uses a diverse-redundant design• Four output switching channels for connection to control-reliable powerinterrupt circuits• Auto reset or monitored manual reset• Auxiliary non-safety outputs for status monitoring by process controller: oneelectromechanical “hard” contact, plus two solid-state outputs• Design complies with standards UL991, EN 418, and EN 954-1(Safety Category 4)• For use in functional stop category 0 applications per NFPA 79and EN 418• 5 amp safety output contacts• Plug-in terminal blocksBuy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com