Manual 2100-594Page 4 of 19WALL MOUNT GENERAL INFORMATIONAIR CONDITIONER WALL MOUNT MODEL NOMENCLATUREW 48 A 2 3 A 10 B X X X X ANOTE: Vent option B is without exhaust capability. May require separate field supplied barometric relief in building.SHIPPING DAMAGEUpon receipt of equipment, the carton should bechecked for external signs of shipping damage. Ifdamage is found, the receiving party must contactthe last carrier immediately, preferably in writing,requesting inspection by the carrier’s agent.GENERALThe equipment covered in this manual is to be installedby trained, experienced service and installationtechnicians.The refrigerant system is completely assembled andcharged. All internal wiring is complete.The unit is designed for use with or without duct work.Flanges are provided for attaching the supply and returnducts.These instructions explain the recommended methodto install the air cooled self-contained unit and theelectrical wiring connections to the unit.These instructions and any instructions packaged withany separate equipment required to make up the entireair conditioning system should be carefully read beforebeginning the installation. Note particularly “StartingProcedure” and any tags and/or labels attached to theequipment.While these instructions are intended as a generalrecommended guide, they do not supersede anynational and/or local codes in any way. Authoritieshaving jurisdiction should be consulted before theinstallation is made. See Page 3 for information oncodes and standards.Size of unit for a proposed installation should be basedon heat loss calculation made according to methodsof Air Conditioning Contractors of America (ACCA).The air duct should be installed in accordance with theStandards of the National Fire Protection Associationfor the Installation of Air Conditioning and VentilatingSystems of Other Than Residence Type, NFPA No.90A, and Residence Type Warm Air Heating and AirConditioning Systems, NFPA No. 90B. Where localregulations are at a variance with instructions, installershould adhere to local codes.KWMODEL NUMBER CONTROL MODULES(See Spec. Sheet S3402)VOLTS & PHASEA - 230/208/60/1REVISIONSVENTILATION OPTIONSB - Blank-off PlateFILTER OPTIONSX - No Filters RequiredCOLOR OPTIONSX - Beige (Standard)1 - White4 - Buckeye Gray5 - Desert Brown8 - Dark BronzeCOIL OPTIONSX - Standard1 - Phenolic Coated Evaporator2 - Phenolic Coated Condenser3 - Phenolic Coated Evaporatorand CondenserOUTLET OPTIONSX - Front (Standard)CAPACITY48 - 4 Ton60 - 5 TonA - Air ConditionerL - Left Hand Air Conditioner3 - 3 Ton Air Openings on 5 Ton Cabinet