HandscannersBCS 3600ex series7 Connection /commissioning (qualifiedpersonnel)Subject to technical modifications17/05/18 47 / 727.2 Universal supply module7.2.1 Establishing universal supply module connectionsDANGERNon-approved accessories!Loss of function and risk of explosion. Only use universal supply modules that have been specified for the relevant configuration byBARTEC.The approved accessories are shown in the system overview (see system overview, Chapter 15.2,P. 70). The model is clearly indicated on the type label. The universal supply module is mounted to a secure base.1. When using the wired hand-held scanner: connect the connection cable of the hand-heldscanner to the universal supply module, turning the connection cable clockwise to screw tight.2. When using the Bluetooth hand-held scanner: connect the hand-held scanner via pairing to theuniversal supply module (see Chapter 6.4.1, P. 41).3. Feed the connection cable for the power supply through the cable gland into the universalsupply module.4. Feed the data cable between the PC and universal supply module through the cable gland intothe universal supply module.5. Connect the connection cable for the power supply to the universal supply module according tothe terminal connection plan (see Chapter 4.6.1, P. 32).6. Connect the data cable between the PC and universal supply module to the universal supplymodule according to the terminal connection plan and interface type (see Chapter 4.6.1, P. 32).7. Check connections and terminal assignments.8. Connect data cable between the PC and universal supply module to the PC.9. Set the DIP switch (see Chapter 4.6.2, P. 33 for configuration).10. Close the cover of the universal supply module.11. Connect the connection cable for the power supply to the power source.12. For connection to an HID device or to a PLC: note further information on the interfaces (HIDdevice: see Chapter 7.2.2, P. 48; PLC: see Chapter 7.2.3, P. 48)