Basic Operation and FeaturesBasler A400k 3-25DRAFT3.8.1 Area of Interest Setup RulesWhen setting up the area of interest, observe the following rules:• Starting columns can only be selected in multiples of 16 (+1), that is, the starting column canbe 1, 17, 33, and so on.• The width can only be multiples of 16, that is, 16, 32, 48, and so on.• The sum of the setting for the starting column plus the setting for the width in columns cannot exceed 2353.• The sum of the setting for the starting line plus the setting for the height in lines can notexceed 1727.3.8.2 Setting the Area of InterestYou can set the area of interest by using the Camera Configuration Tool Plus (CCT+), by usingbinary write commands from within your own application to set the camera’s control and statusregisters (CSRs) or by using the AOI Editor.With the CCT+With the CCT+ (see Section 4.1), you use the AOI Starting Column, AOI Width, AOI Starting Line,and AOI Height settings in the Area of Interest parameters group to set the area of interest.By Setting CSRsYou can set the AOI starting column by writing a value to the Starting Column field of the AOIStarting Column CSR (see page 4-25).You can set the AOI width by writing a value to the Width field of the AOI Width CSR (see page 4-27).You can set the AOI starting line by writing a value to the Line field of the AOI Starting Line CSR(see page 4-28).You can set the AOI height by writing a value to the Height field of the AOI Height CSR (see page4-29).See Section 4.2.2 for an explanation of CSRs. See Section 4.3.1 for an explanation of using read/write commands.With the AOI EditorYou can set an AOI using the AOI Editor (see Section 3.8.4.2). This involves entering the settingsof one AOI in the AOI list of the AOI Editor.