Table 1-1. Special-Order DGC-500 ControllersPart Number Style Number Special Features9355400111 F5J0 400 Hz nominal frequency9355400112 F1J09355400127 F5J19355400128 F1J19355400113 F5J0 cURus recognized for use inhazardous locations9355400114 F1J09355400129 F5J19355400130 F1J1SPECIFICATIONSCurrent SensingAccuracy: ±1% of full scale or ±2 A, whichever is greaterBurden: 1 VATerminals: P10, P11 (A-phase)P12, P14 (B-phase)P15, P17 (C-phase)1 Ampere InputsContinuous Rating: 0.02 to 1.0 A1 Second Rating: 2 A5 Ampere InputsContinuous Rating: 0.1 to 5.0 A1 Second Rating: 10 AVoltage SensingAccuracy: ±1% of full scale or ±2 V, whichever is greaterBurden: 1 VARange: 12 to 576 V rms, line-to-line1 Second Rating: 720 V rmsTerminals: P23 (A-phase), P26 (B-phase), P29 (C-phase), P30 (Neutral)FrequencyAccuracy: ±0.25% of reading or ±0.2 Hz, whichever is greaterDisplay Range: 4 to 70 Hz4 to 450 Hz (P/N 3555400111, 9355400112 only)Contact SensingEmergency Stop InputType: Normally-closed dry contactsTerminals: P35, P39Programmable Inputs (3)Type: Normally-open dry contactsTerminals: P2, P21 (Input 1)P3, P21 (Input 2)P4, P21 (Input 3)9355400990 Rev H DGC-500 General Information 1-3