Valid for FlexTop™ 2202 / 2211 / 2221The FlexProgrammer configuration unit must not be connected to theFlexTop within the hazardous area.Configuration procedure:a. Disconnect mains from the 4...20 mA loop circuitb. Disconnect the product from the circuitry within the hazardous areac. Bring the product to the safe aread. Connect the FlexProgrammer and perform the configuratione. Reinstall the product in the hazardous areaf. Connect the power supply to the circuitValid for FlexTop™ 2221 onlyConfiguration for the FlexTop™ 2221 can be made within the hazardousarea by means of a handheld HART configurator, providing the precau-tions and guidelines described in the product’s manual are observed.www.baumer.com Page 1 / 162019-10-29 Design and specifications subject to change without noticeCombiTemp™ TCR6 is a temperature sensor, based on RTD technolo-gy, which is designed and produced to meet the requirements in generalindustry where threaded connections are used.CombiTemp™ TCR6 comprises a series of basic elements which can becombined in various ways to a CombiTemp TCR6 temperature sensor.The product offers great flexibility in respect to modification, service andmaintenance.The sensor can be made to feature a RTD output signal or with a built inFlexTop™ temperature transmitter types 2202, 2211, 2221 with 4-20 mAoutput and the type 2231 with Profibus output (for documentation ofFlexTops, please see relevant data sheet or operating instructions).DescriptionSafety instructionsThis instrument is built and tested according to the current EU-directivesand packed in technically safe conditions. In order to maintain this condi-tion and to ensure safe operation, the user must follow the hints andwarnings given in this instruction.During the installation the valid national rules have to be observed. Ig-noring the warnings may lead to severe personal injury or substantialdamage of property.The product must be operated by trained staff. Correct and safe opera-tion of this equipment is dependent on proper transport, storage installa-tion and operation.All electrical wirings must conform to local standards. In order to preventstray electrical radiation, we recommend twisted and shielded inputcables and also to keep power supply cables separated from the inputcables. The connection must be made according to the connection dia-grams.Before switching on the power supply take care that other equipment isnot affected. Ensure that the power voltage and the conditions is theenvironment comply with the specification of the device.Before switching of the power supply voltage, check the possible effectson other equipment and the processing system.ATEX application - configurationWARNINGFor electrical installations and commissioning of the explosion protecteddevices, the data given in the conformity certificate as also the localregulations for installation of electrical apparatus within explosion pro-tected areas must be considered. The intrinsically safe versions can bemounted in the explosion hazarded area according to its specificationand only connected to a certified intrinsically safe supply loop with thecorresponding electrical values.After mounting of the device - do check that the housing has a groundpotential.The product contains not replaceable parts, except from insert and/orFlexTop transmitter if selected. In case of malfunction the product mustbe sent to Baumer for repair.Technical specificationsSensor and connection material Stainless steel, AISI 316LHousingM16 3 … 9 mmM16 5 … 9 -M20 8 … 13 -Media temperature -50...400°C on sensor tube tipAmbient temperature (cable) -50...160°C w. RTD output-50...85°C w. transmitterEnvironmentPressure ≤100 barHumidity <98% RH, condensingProtection class IP65Vibrations GL, test 2 (sensor tube <200 mm)English page 1...4Deutsch Seite 5...8Français page 9...12Operating instructions: 11119033 08Operating instructions for temperature sensorTCR6Industrial temperature sensor