CAIRE FreeStyle Quick Reference Manual
Also see for FreeStyle: User manualProvider technical service manualQuick start guideManual
Contact Customer Support 1-800-482-2473 or Technical Service 770-721-7759Copyright © 2014 Chart Industries ML-CONC0028 BCAIRE Inc. reserves the right to discontinue its products, or change the prices, materials, equipment, quality,descriptions, specifications and/or processes to its products at any time without prior notice and with no furtherobligation or consequence. All rights not expressly stated herein are reserved by us, as applicable.Alarm/Light IndicatorsWhen a pulse of oxygen is sent through the nasal cannula, the green light above the selected flow setting flashes each time a breath isdetected.Start-Up: A brief alarm sounds at start-up.Low Battery: As battery power approaches a low level, a brief alarm sounds intermittently, and the yellow 25% BATT light also flashesintermittently.Cannula Disconnected: When unit is operating but does not sense breathing, (15 minutes) a constant alarm sounds with the red light.FreeStyle’s Capacity is Exceeded: If breathing rate causes the capacity of unit to be exceeded, a rapid alarm sounds with the red light.(When this occurs, the concentration of oxygen is dropping below unit specifications.)General Malfunction: If unit has a general malfunction, a rapid alarm sounds, and the red alarm light illuminates continuously. (Whenthis occurs, the concentration of oxygen is dropping below unit specifications.)Service Indicator/Alarm: When the alarm service/indicator illuminates (yellow), it is recommended that the FreeStyle be serviced by theEquipment Provider. This will illuminate every 5,000 hours and after service will be reset.Filter—Air intakeAt least one time each week, remove the inlet cover on the lower front of the unit, and wash the air intake filter. Allow to dry thoroughly.Checking Oxygen Concentration1. Connect the FreeStyle to AC power (plug it into the wall).2. Open the cover of the control panel and press flow setting [2].3. Activate the unit’s test mode by pressing flow setting [1] and [3] simultaneously for 10 seconds. After 10 seconds, the alarm will beepand the unit will then start to auto pulse in flow setting 3.4. Verify FreeStyle is pulsing, (you should be able to hear the pulse of oxygen and see the Light turn off momentarily above the flowsetting). Allow FreeStyle to run for 5 minutes before connecting the oxygen analyzer.5. With a short length of tubing, connect a calibrated oxygen analyzer to the oxygen outlet and record the unit’s concentration. Theconcentration specification in test mode is 90% -3%/+5%. Note: Fast response fuel cell analyzer are recommended.Nasal Cannula & TubingThe FreeStyle unit uses a standard nasal cannula. Tubing and/or cannula should not exceed 25 feet (7.62 m).Sleep ModeThere may be times when the unit will not power on from battery power even though the battery shows that it is still charged. Most likely, theunit has gone into Sleep Mode. All new and refurbished FreeStyle units are shipped from the factory in Sleep Mode. Sleep mode can also occurif the internal battery has been removed or replaced, or if the unit has been unused and sitting for some time. To bring the unit out of SleepMode, simply plug the unit into AC power, this will awaken the unit and allow it to run normally under battery power.Hour MeterThe FreeStyle contains a digital hour meter that is mounted internally on the circuit board. It is visible by removing the front case of the unit.The hour meter is dual function. It contains a setting to display both total hours and maintenance hours. The maintenance hours are indicatedby a wrench on the display. A button to the right of the meter is used to toggle between the two modes. Holding the button for 3 seconds re-sets the maintenance hours and clears the yellow service light that illuminates at 5,000 hours.Routine MaintenanceThe FreeStyle POC requires minimal maintenance. Perform the following steps below to ensure proper maintenance and function.1. Concentration Check – Schedule the unit for purity/concentration checks according to your company policy.2. Air Intake/Gross Particle Filter – located on the lower front panel, this filter should be washed weekly. Allow to dry thoroughly.3. Service Check – Every 5000 hours the yellow service light/Light in the upper left corner of the control panel will illuminate continuously,indicating compressor check.4. Product Filter – This internal filter must be replaced every 10,000 hours. |
Related manuals for CAIRE FreeStyle
CAIRE FreeStyle 5 Quick Reference Manual
CAIRE FreeStyle Manual
CAIRE AirSep VisionAire 5 Quick Reference Manual
CAIRE FreeStyle Comfort User Manual
CAIRE FreeStyle Comfort User Manual
CAIRE FreeStyle Comfort Technical Manual
CAIRE VisionAire 5 User Manual
CAIRE HELiOS U36 User Manual
CAIRE Eclipse 5 User Manual
CAIRE Companion 5 User Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine