4654DIN 18650BS 7036EN 160053,50 m3 m2,50 m2 md max = 2,5 m d max = 3 m3,50 m3 m2,50 m2 mmax.9 cm**+++ORWIDTHAdditionaladjustmentsare possible byLCD or remotecontrol(see p. 5)Part of the detection field can be masked to reduce it.The arrow position determines the width of the detection field.INFRARED SAFETY FIELDCLOSERAWAYIf necessary, adjust the IR-curtainangle (from -7° to 4°, default 0°).Activate the visible* spots to verifythe position of the IR-curtain.ANGLESETUPTEST THE GOOD FUNCTIONING OF THE INSTALLATION BEFORE LEAVING THE PREMISES!SETTINGS* Visibility depends on external conditions. When spots are not visible, use MRSP to locate the curtains.** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor shouldalways be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf.The size of the detection field varies according to themounting height and the settings of the sensor.The full door width must be covered.ORSTANDARD: standard in- and outdoor installationsCRITICAL ENVIRONMENT: critical installations due to surroundings or weatherSHOPPING STREET: installations in narrow streets with pedestrian trafficMountingheightDetectionwidth2.00 m2.20 m2.50 m3.00 m3.50 m2.00 m2.20 m2.50 md maxd maxChoose one of the following presettings or adjust the sensor manually (see p.5):Always verify the actual detection field widthwith a piece of paper and not MRSP, whichdetects the whole emitted field.3.50 m3 m2.50 m2 md max = 2.5 m3.50 m3 m2.50 m2 mDOORSETUP 1 (QUICK)SETUP 2 (ASSISTED)OR2 s4 sSTEP OUT OF THE INFRARED FIELD!reference picturetest of full door cycle +reference pictureMR8700 / FA00361M06 ☜☞ IXIO-DT3 / 42.8638 / v1 - 02.16