Installing the 9A600 Module2-4The Module Card DIP SwitchAn eight position DIP switch is located on the module card as shown inFigure 2-3. The functions of the switches are listed in Table 2-1.Table 2-1. Function of the DIP Switch!CAUTIONDo not toggle Switch 8 unless you intend to reset the user configured passwordsto their factory default settings.Do not toggle Switch 7 unless you intend to reset the user parameters to thefactory default settings. Refer to the 9A656-04 and 9A600 Configuration Guidefor instructions on the parameters that may be configured by the user viaLocal/Remote Management.Switch Function Description8 ClearPasswordWhen toggled, this switch clears user-enteredpasswords stored in NVRAM, and restores thedefault passwords. Once reset you can use thedefaults or enter new passwords.7 ClearNVRAMThe module uses NVRAM to store userentered parameters such as IP addresses,device name, etc. To reset these parameters tothe factory defaults, toggle this switch. Oncereset you can use the defaults or enter newparameters which are stored in NVRAM whenthe module is powered down, and remainthere until the switch is toggled again.6 Force BootPDownloadToggling this switch after pulling the boardout of the SmartSwitch 9500, clears downloadinformation from NVRAM and forces imagefiles to be downloaded from the stationconnected to the EPIM on the EnvironmentalModule configured to act as that modules’BOOT P server.5 Reserved For Factory Use Only4 Reserved For Factory Use Only3 Reserved For Factory Use Only2 Reserved For Factory Use Only1 Reserved For Factory Use Only