6 238. If removed, the glass window must be put back onto the unit prior to operating theheater.9. Installation and repairs should be performed by a licensed service person only,refer to back of the instructions for service number.10. For installation into a non-combustible fireplace, i.e.: masonry or brick or into amock fireplace, i.e. timber or plasterboard, the chimney and base should be ofsound construction and be free from cracks and holes (to ensure that sufficientflue draught can be generated).Note: when installing into a mock fireplace a mock fireplace installation kit mustbe used.11. The heater must be properly installed in a working chimney or connected to aventing system. Operation of this heater, when not connected into a workingchimney or a properly installed and maintained venting system can result incarbon monoxide (CO) poisoning and possible death.12. Testing the effectiveness of the flue.Before testing the flue confirm air vents are unobstructed. If an exhaust fan orother heating appliances are present switch them on. This is to test that there isno interaction between the Cannon heater and other appliances.Refer to Australian Standard Gas Installations AS 5601.For ‘air movement not to affect appliance’ see clause 5.2.1.For ‘air supply to appliance’ see clause 5.4.1.For ‘ventilation requirements’ see clause 5.4.3.13. The appliance should be inspected prior to use, with regular inspections(annually) to be made by a licensed service person. It is important that circulatingair passageways of the appliance be kept clean, dirt and lint free, for a safe andefficient operation of the heater.14. The first time you use your heater a smell may occur due to its new condition.This is quite normal and will disappear after a few hours use at the maximumcontrol position.Important:When the heater is operating the mesh guard/glass front is hot. The meshguard, or glass front, fitted to the heater conforms to Australian Standardsrequirements.The guard is fitted to this appliance to reduce the risk of fire or injury fromburns and no part of it should be permanently removed.For protection of young children or the infirm, a second guard is required.StandardsThis appliance meets the following standards (When installed correctly):Standards Australia: AS/NZS 3100AS 5601AS 4553:2008To replace the room circulation fan1. Remove the fascia. Refer page 12 of the installation instructions.2. Remove the front screw retaining the bracket mounting the valve controls (whitebox). Move the bracket and controls to the front of the heater.3. Disconnect the fan plug from the plug carrier. Remove the two M5 wing nuts whichlocate the fan to the fan chamber underside. Lower fan from male thread.4. Disconnect the silicone tubes from the fan pressure switch. Remove fan from fanchamber.5. Remove the venturi and bracket from the fan removed from the heater. Insert andsecure the venturi and bracket on replacement fan. Note “TOP” should point to air outletof fan.6. Insert fan into chamber ensuring that the venturi is not disturbed. Locate fan onto malethread. Secure with M5 wing nuts, ensuring rubber buffer locates over thread.7. Replace silicone tubes onto fan pressure switch ensuring that the black tube isconnected to the black side of the pressure switch. Check to make sure that the tubesare not kinked or pinched.8. Reconnect fan plug into plug carrier. Test operation of room circulation fan and fanpressure switch - turn heater on low heat. The fan should operate immediately. Thereshould be a 5-10 second delay for the fan pressure switch to energise depending onroom temperature.To replace fan pressure switch1. Remove the fascia. Refer page 12 of theinstallation instructions.2. Remove the screw retaining the bracketmounting the valve controls (white box).Move the bracket and controls to the frontof the heater.3. Remove the connecting wiring from thepressure switch.4. Remove the silicone tubes from the pressure switch.5. The pressure switch is secured onto the rear of the fan chamber housing two M4screws.6. Replace the pressure switch. For wiring, one wire to “C” (common) and the otherconnect to “NO” (Normally open). Polarity not important.7. Re-attach silicone tubes making sure that the black tube attaches to the black side ofthe pressure switch. Make sure that the tubes are not pinched or kinked.7. Test operation of fan pressure switch - turn heater on low heat. There should be a 5-10second delay for the fan pressure switch to energise depending on room temperature.30