8Electrical connectionPower supply voltage and frequency: 220-240V a.c. 50 Hz.Note: the supply cable must be positioned so that it never reaches at any point a temperature 50°C higher than theroom temperature. The cable must be routed away from the rear vents. Should you require it, you may use a longercable, however, you must ensure that the cable supplied with the appliance is replaced by one of the samespecifications in accordance with current standards and legislation.Your appliance is supplied with a 13 amp fused plug that can be plugged into a 13 amp socket for immediate use.Before using the appliance please read the instructions below.WARNING - THIS APPLIANCE MUST BE EARTHED.THE FOLLOWING OPERATIONS SHOULD BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.Replacing the fuse:When replacing a faulty fuse, a 13 amp ASTA approved fuse to BS 1362 should always be used, and the fusecover re-fitted. If the fuse cover is lost, the plug must not be used until a replacement is obtained.Replacement fuse covers:If a replacement fuse cover is fitted, it must be of the correct colour as indicated by the coloured marking or thecolour that is embossed in words on the base of the plug. Replacements can be obtained directly from yournearest Service Depot.Removing the plug:If your appliance has a non-rewireable moulded plug and you should wish to remove it to add a cable extension orto re-route the mains cable through partitions, units etc., please ensure that either:• the plug is replaced by a fused 13 amp re-wireable plug bearing the BSI mark of approval.or:• the mains cable is wired directly into a 13 amp cable outlet, controlled by a switch, (in compliance with BS5733) which is accessible without moving the appliance.Please note: for appliances with a rating greater than 13 amp (eg: electric hob, double ovens and freestandingelectric cookers etc.) the mains cable must be wired into a cooker output point with a rating of 45 amp. In this casethe cable is not supplied.Disposing of the plug:Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentallyinserted into a socket. Instructions for connecting cable to an alternative plug:Important: the wires in the mains lead are coloured in accordance with the following code:Green & Yellow - EarthBlue - NeutralBrown - LiveIf the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminalsin your plug, proceed as follows:Connect Green & Yellow wire to terminal marked “E” or 66666 or coloured Green or Green & Yellow.Connect Brown wire to terminal marked “L” or coloured Red.Connect Blue wire to terminal marked “N” or coloured Black.If a 13 amp plug (BS 1363) is used it must be fitted with a 13 amp fuse. A 15 amp plug must be protected by a 15amp fuse, either in the plug or adaptor or at the distribution board. If you are in any doubt about the electrical supplyto your machine, consult a qualified electrician before use.How to connect an alternative plug:The wires in this mains lead are coloured in accordance with the following code:BLUE “NEUTRAL” (“N”)BROWN “LIVE” (“L”)GREEN AND YELLOW “EARTH” (“E”) GREEN &YELLOWBROWNBLUE13 amp fuseCROSS-BARCORD GRIP