88 8-178-17Service Mode > TESTMODE > NETWORK > SSSWService Mode > TESTMODE > NETWORK > SSSW● RELAY-1TESTMODE>FAX>MODEM>RELAY-1Sub item Description FAX model onlyCML Test ON/OFF of port SW and relay on NCUSetting value: ON, OFF YesH Test ON/OFF of port SW and relay on NCUSetting value: ON, OFF Yes■ FACULTYTESTMODE>FAX>FACULTYSub item Description FAX model onlyG34800TX Transmit the frequency of 4800bps using G3 signal transmissionfunction after DC circuit closure. YesDETECT1 Ring detectionCheck the status (ON, OFF) of hook and Ci, Fc from i line. YesDETECT2 CNG detection test 1Execute CNG signal check and FED check.Detect CNG after CML relay is ON.YesDETECT3 CNG detection test 2Execute CNG signal check and FED check.Detect CNG after CML relay is OFF.Yes■ PANELTESTMODE>FAX>PANELSub item DescriptionKEY CHECK START Key check[Applicable case]Check if all keys functions normally after replacement of Control Panel.LED CHECK START LED check[Applicable case]Check if all LEDs are lit normally after replacement of Control Panel.LCD CHECK START LCD check[Applicable case]Check if LCD can display without any missing dot after replacement ofControl Pannel.T-8-48T-8-49T-8-50NETWORK■ SSSWNETWORK>SSSWSub item BIT DescriptionSW01 ~ SW090Not in use1234567SW10Network ConfigSystem0Not in use123 Turn ON(Enable)/ OFF(Disable) for acquisition of host name (Option 12) byDHCPDefault value: 04 Turn ON(Enable)/ OFF(Disable) for registration of host name (Option 81) byDHCPDefault value: 15Not in use67SW11 ~ SW500Not in use1234567T-8-51