WIRING DIAGRAMSRefer to Fig. 6 and 7 for wiring diagrams.TROUBLESHOOTINGRefer to the service label. (See Fig. 9—Service Label.)The Troubleshooting Guide following Fig. 9 can be a useful toolin isolating furnace operation problems. Beginning with the word“Start,” answer each question and follow the appropriate arrow tothe next item.The Guide will help to identify the problem or failed component.After replacing any component, verify correct operation sequence.Fig. 9—Service LabelA00286LED CODEIfstatuscode recallisneeded, briefly removethenreconnectonemain limitwire to display stored statuscode.SERVICEToinitiate thecomponenttestsequence,shutOFF theroom thermostatordisconnectthe "R" thermostatlead.Brieflyshortthe TEST/TWINterminalto the "Com24V"terminal.StatusLEDwillflashcodeandthen turnON theinducermotor athigh speed untiltheend ofthe test,then shiftto low speedfor10 seconds.Thehotsurface ignitor,blower motor low-heatspeed,blower motorhigh-heatspeed,andblowermotorcoolspeed willbeturned ON for10-15secondseach.GasValve and Humidifierwill not beturned on. 326379-101 REV.A (lit-top)CONTINUOUSOFF-Check for115VAC atL1andL2,and24VAC atSEC-1and SEC-2.CONTINUOUSON -Control has 24VACpower.RAPID FLASHING -Line voltage (115VAC) polarity reversed.Iftwinned,refer to twinningkit instructions.EACHOF THEFOLLOWINGSTATUS CODESIS ATWO DIGITNUMBERWITHTHE FIRSTDIGITDETERMINEDBYTHENUMBER OF SHORTFLASHES AND THE SECOND DIGITBY THE NUMBER OF LONG FLASHES.STATUSCOMPONENT TEST11 NO PREVIOUS CODE -Storedstatuscodes areerased automatically after72hours.12 BLOWER ON AFTERPOWER UP(115 VACor 24VAC) -Blower runs for 90 seconds, if unit ispoweredupduringacallforheat(R-Wclosed).13 LIMIT,DRAFT SAFEGUARD,FLAME ROLL-OUTSWITCH OR BLOCKED VENTSWITCH (when used)LOCKOUT- Control will autoreset after threehours.Reset switch.Refer to #33.14 IGNITION LOCKOUT- Control will auto-reset after threehours. Refer to#34.21 GAS HEATING LOCKOUT - Control will NOTautoreset.Check for:- Mis-wiredgas valve - Defectivecontrol (valverelay)22 ABNORMAL FLAME-PROVING SIGNAL- Flameisprovedwhilegasvalveisde-energized. Inducer will rununtilfaultis cleared.Check for:-Leaky gas valve -Stuck-open gasvalve23 PRESSURE SWITCH DID NOTOPEN Check for:- Obstructed pressure tubing. -Pressure switch stuck closed.24 SECONDARY VOLTAGE FUSEIS OPENCheck for: -Shortcircuitinsecondary voltage(24VAC)wiring.31 HIGH-HEAT PRESSURESWITCHOR RELAY DIDNOTCLOSE ORREOPENEDCheck for: Control relaymay bedefective - Refer to#3232 LOW-HEAT PRESSURE SWITCH DIDNOT CLOSE OR REOPENED Ifopenlongerthan fiveminutes,inducershutsofffor15 minutes before retry.Checkfor:-Properventsizing-Defective inducermotor - Disconnectedor obstructedpressuretubing- Excessive wind - Defective pressure switch- Restrictedvent -Inadequatecombustionair supply-Low inducervoltage(115VAC)ifcode flashes whileunitruns inlow-heatwith highspeed inducer.Ifitopensaftertrialforignitionperiod,blowerwill comeonfor 90second recycle delay.33 LIMIT,DRAFT SAFEGUARD,FLAME ROLL-OUTSWITCH OR BLOCKED VENTSWITCH (when used)LOCKOUT ISOPEN -Ifopen longerthan three minutes,code changes to #13.Flameroll-outswitchrequiresmanualreset.Checkfor: -Defective blowermotororcapacitor.-Dirty filterorrestricted ductsystem. -Restricted vent-Loose blowerwheel. -Defective switch or connections.-Properventsizing -Excessive wind-Inadequate combustionairsupply(Flame Roll-outSwitchopen).-OpenFlameRoll-outswitch.Manualresetorreplace.34 IGNITIONPROVINGFAILURE - Control willtrythreemoretimesbefore lockout #14 occurs.Ifflamesignallostaftertrialforignitionperiod,blowerwillcome on for90second recycledelay.Checkfor:-Oxidebuildup on flamesensor(cleanwith fine steelwool).-Properflamesense microamps (.5 microamps D.C.min.,4.0 -6.0nominal).-Gasvalve defectiveorgasvalve turned off.- DefectiveHot SurfaceIgnitor - Manual valveshut-off.-Low inletgaspressure. -Controlground continuity-Inadequateflame carryoverorrough ignition.-Flamesensormustbe ungrounded.- Green/Yellowwire MUSTbeconnected tofurnace sheetmetal.43 LOW-HEAT PRESSURE SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSEDCheck for: -Pressure switch stuckopen -Disconnected orobstructed pressure tubing45 CONTROLCIRCUITRY LOCKOUT Auto-resetafterone hourlockoutdueto;- Flamesense circuit failure - Softwarecheckerror - Gas valverelaystuckopenResetpowerto clearlockout.Replace controlifstatus coderepeats.A002869