4CONTENTS (cont)PageOptional Pumpout System Maintenance . . . . . . . . . 81• OPTIONAL PUMPOUT COMPRESSOR OILCHARGE• OPTIONAL PUMPOUT SAFETY CONTROLSETTINGSOrdering Replacement Chiller Parts . . . . . . . . . . . . . 81TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . 82-137Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82Checking Display Messages. . . . . . . . . . . . . . . . . . . . . 82Checking Temperature Sensors . . . . . . . . . . . . . . . . . 82• RESISTANCE CHECK• VOLTAGE DROP• CHECK SENSOR ACCURACY• DUAL TEMPERATURE SENSORSChecking Pressure Transducers. . . . . . . . . . . . . . . . . 82• COOLER CONDENSER PRESSURE TRANSDUCERAND OPTIONAL WATERSIDE FLOW DEVICECALIBRATION• TRANSDUCER REPLACEMENTControl Algorithms Checkout Procedure . . . . . . . . 83Control Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84Control Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100• RED LED (Labeled as STAT)• GREEN LED (Labeled as COM)Notes on Module Operation . . . . . . . . . . . . . . . . . . . . 100Chiller Control Module (CCM) . . . . . . . . . . . . . . . . . . 100• INPUTS• OUTPUTSReplacing Defective Processor Modules . . . . . . . 101• INSTALLATIONGateway Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 102• DRIVE STATUS INDICATOR• MS STATUS INDICATOR• NET A STATUS INDICATOR• NET B STATUS INDICATORPhysical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103APPENDIX — 19XRV LIQUIFLO™ 2 ICVCPARAMETER INDEX. . . . . . . . . . . . . . . . . . . . . . 138-146INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147INITIAL START-UP CHECKLIST FOR19XRV HERMETIC CENTRIFUGALLIQUID CHILLER . . . . . . . . . . . . . . . . . . . .CL-1 to CL-12INTRODUCTIONPrior to initial start-up of the 19XRV unit, those involved inthe start-up, operation, and maintenance should be thoroughlyfamiliar with these instructions and other necessary job data.This book is outlined to familiarize those involved in thestart-up, operation, and maintenance of the unit with the con-trol system before performing start-up procedures. Proceduresin this manual are arranged in the sequence required for properchiller start-up and operation.ABBREVIATIONS AND EXPLANATIONSFrequently used abbreviations in this manual include:Words printed in all capital letters or in italics may beviewed on the International Chiller Visual Controller (ICVC)(e.g., LOCAL, CCN, ALARM, etc.).Words printed in both all capital letters and italics can alsobe viewed on the ICVC and are parameters (e.g., CONTROLMODE, COMPRESSOR START RELAY, ICE BUILDOPTION, etc.) with associated values (e.g., modes, tempera-tures, percentages, pressures, on, off, etc.).Words printed in all capital letters and in a box representsoftkeys on the ICVC control panel (e.g., , ,, , etc.).This unit uses a microprocessor control system. Do notshort or jumper between terminations on circuit boards ormodules; control or board failure may result.Be aware of electrostatic discharge (static electricity) whenhandling or making contact with circuit boards or moduleconnections. Always touch a chassis (grounded) part todissipate body electrostatic charge before working insidethe VFD enclosure.Use extreme care when handling tools near boards andwhen connecting or disconnecting terminal plugs. Circuitboards can easily be damaged. Always hold boards by theedges and avoid touching components and connections.This equipment uses, and can radiate, radio frequencyenergy. If not installed and used in accordance with theinstruction manual, it may cause interference to radiocommunications. It has been tested and found to complywith the limits for a Class A computing device pursuant toSubpart J of Part 15 of FCC Rules, which are designed toprovide reasonable protection against such interferencewhen operated in a commercial environment. Operation ofthis equipment in a residential area is likely to causeinterference, in which case the user, at his own expense,will be required to take whatever measures may berequired to correct the interference.Always store and transport replacement or defective boardsin anti-static shipping bag.CCM — Chiller Control ModuleCCN — Carrier Comfort Network®CCW — CounterclockwiseCW — ClockwiseECDW — Entering Condenser WaterECW — Entering Chilled WaterEMS — Energy Management SystemHGBP — Hot Gas BypassI/O — Input/OutputICVC — International Chiller Visual ControllerLCD — Liquid Crystal DisplayLCDW — Leaving Condenser WaterLCW — Leaving Chilled WaterLED — Light-Emitting DiodeOLTA — Overload Trip AmpsPIC III — Product Integrated Controls IIIRLA — Rated Load AmpsSI — International System of UnitsTXV — Thermostatic Expansion ValveVFD — Variable Frequency DriveENTER EXITINCREASE QUIT