249 - OPTION FOR HIGH CONDENSING TEMPERATURE (OPTION 150)9.1 - Physical data, units with option 150Standard-efficiency units (option 150)30XW--/30XWH 254 304 354 402 452 552 602 652 702 802 852 1002 1052 1154 1252 1352 1452 1552 1652 1702Sound levels - unit with option 150Sound power level(1) dB(A) 95 95 95 99 99 99 99 102 102 102 102 102 102 102 105 105 105 105 105 105Sound pressure level at 1 m(2) dB(A) 78 78 78 82 82 82 82 84 84 84 84 84 84 84 86 86 86 86 86 86Sound levels - unit with option 150 + option 257(3)Sound power level (1) dB(A) - - - 96 96 96 96 100 100 100 100 99 99 99 103 103 103 103 103 103Sound pressure level at 1 m(2) dB(A) - - - 78 78 78 78 82 82 82 82 80 80 80 84 84 84 84 84 84Dimensions - unit with option 150Length mm 2724 2724 2724 2741 2741 2741 2741 3059 3059 3059 2780 4025 4025 4025 4730 4730 4730 4730 4790 4790Width mm 928 928 928 936 936 936 936 1090 1090 1090 1090 1036 1036 1036 1201 1201 1201 1201 1947 1947Height mm 1567 1567 1567 1692 1692 1692 1692 1858 1858 1858 1920 1870 1870 1925 2071 2071 2071 2071 1535 1535Operating weight(4) kg 2017 2036 2072 2575 2575 2613 2644 3407 3438 3462 3672 5370 5408 5698 7233 7554 7622 7670 9006 9032Compressors Semi-hermetic 06T screw compressors, 50 r/sCircuit A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1Circuit B - - - - - - - - - - - 1 1 1 1 1 1 1 1 1Refrigerant(4) R-134aCircuit A kg 84 80 78 82 82 82 82 145 135 125 158 85 85 105 120 115 110 105 195 195teqCO2 120 114 112 117 117 117 117 207 193 179 226 122 122 150 172 164 157 150 279 279Circuit B kg - - - - - - - - - - - 85 85 105 120 115 110 105 195 195teqCO2 - - - - - - - - - - - 122 122 150 172 164 157 150 279 279Oil - unit with option 150 SW220Circuit A l 23.5 23.5 23.5 32 32 32 32 36 36 36 36 32 32 32 36 36 36 36 36 36Circuit B l - - - - - - - - - - - 32 32 32 32 36 36 36 36 36Capacity control Touch Pilot, electronic expansion valves (EXV)Minimum capacity (5) % 30 30 30 30 30 30 30 15 15 15 15 15 15 15 10 10 10 10 10 10Evaporator Multi-pipe flooded typeNet water volume l 50 56 61 70 70 70 70 109 109 109 98 182 182 205 301 301 301 301 354 354Water connections (Victaulic) in 5 5 5 5 5 5 5 6 6 6 6 6 6 8 8 8 8 8 8 8Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Condenser Multi-pipe flooded typeNet water volume l 55 55 55 76 76 76 76 109 109 109 137 193 193 193 340 340 340 340 426 426Water connections (Victaulic) in 5 5 5 5 5 5 5 6 6 6 8 8 8 8 8 8 8 8 8 8Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000High-efficiency units (option 150)30XW-P/30XWHP 512 562 712 812 862 1012 1162 1314 1464 1612 1762Sound levels - unit with option 150Sound power level (1) dB(A) 99 99 102 102 102 102 102 105 105 105 105Sound pressure level at 1 m (2) dB(A) 82 82 84 84 84 83 83 86 86 86 86Sound levels - unit with option 150 + option 257(3)Sound power level (1) dB(A) 96 96 100 100 100 99 99 103 103 103 103Sound pressure level at 1 m (2) dB(A) 78 78 82 82 82 80 80 84 84 84 84Dimensions - unit with option 150Length mm 3059 3059 3290 3290 3290 4730 4730 4730 4730 4832 4832Width mm 936 936 1105 1105 1105 1039 1039 1202 1202 2174 2174Height mm 1743 1743 1970 1970 1970 1997 1997 2071 2071 1585 1585Operating weight(4) kg 2981 3020 4072 4117 4145 6872 6950 7721 8059 11225 11279Compressors Semi-hermetic 06T screw compressors, 50 r/sCircuit A 1 1 1 1 1 1 1 1 1 1 1Circuit B - - - - - 1 1 1 1 1 1Refrigerant(4) - unit with option 150 R-134aCircuit A kg 130 130 180 175 170 120 120 130 130 240 250teqCO 2 186 186 257 250 243 172 172 186 186 343 358Circuit B kg - - - - - 120 120 150 130 240 250teqCO 2 - - - - - 172 172 215 186 343 358Oil - unit with option 150 SW220Circuit A l 32 32 36 36 36 32 32 36 36 36 36Circuit B l - - - - - 32 32 32 36 36 36Capacity control Touch Pilot, electronic expansion valves (EXV)Minimum capacity (5) % 30 30 15 15 15 15 15 10 10 10 10Evaporator Multi-pipe flooded typeNet water volume l 101 101 154 154 154 293 293 321 321 473 473Water connections (Victaulic) in 6 6 8 8 8 8 8 8 8 10 10Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000Condenser Multi-pipe flooded typeNet water volume l 103 103 148 148 148 316 316 340 340 623 623Water connections (Victaulic) in 6 6 8 8 8 8 8 10 10 10 10Drain and vent connections (NPT) in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8Max. water-side operating pressure kPa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000(1) In dB ref=10-12 W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)). Measured inaccordance with ISO 9614-1 and certified by Eurovent.(2) In dB ref 20μPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)).For information, calculated from the sound power level Lw(A).(3) Option 257 = Low noise level(4) Weight shown is guideline only. Please refer to the unit nameplate.(5) Minimum unit capacity corresponds to a physical state of the unit and is given for indication only. The actual capacity at this stage depends on operating conditions.
PreviousNext |