Combination Matrix and RatingsT1 T3 T1 T3 T1 T3 T1 T3 T1 T338CKPC18DS70 42TPM018-71 230/1/50 Ducted 18,800 16,500 11.8 9.0 1.593 1.833 4,301 1,833 7.5 8.538CKPC24DS70 42TPM024-71 230/1/50 Ducted 25,000 21,500 11.8 8.8 2.119 2.443 5,721 2,443 9.5 10.838CKPC30DS70 42TPM030-71 230/1/50 Ducted 33,000 28,500 12.0 9.0 2.750 3.167 7,425 3,167 12.0 13.838CKPC36DS70 42TPM036-71 230/1/50 Ducted 37,000 32,500 12.2 9.5 3.033 3.421 8,189 3,421 13.2 15.238CKPC36DS90 42TPM036-71 400/3/50 Ducted 37,000 32,500 12.2 9.5 3.033 3.421 8,189 3,421 5.0 5.738CKPS42DS90 42TPM042-71 400/3/50 Ducted 42,000 39,500 12.7 9.6 3.307 4.115 8,929 4,115 5.5 6.538CKPS48DS90 42TPM048-71 400/3/50 Ducted 47,500 43,000 12.2 9.0 3.893 4.778 10,511 4,778 6.6 7.838CKPS60DS90 42TPM060-71 400/3/50 Ducted 60,000 51,000 11.8 8.3 5.085 6.145 13,730 6,145 8.5 10.038CKPC18DS10 42TPM018-11 240/1/50 Ducted 18,800 16,500 11.5 9.0 1.628 1.833 4,396 1,833 7.5 8.438CKPC24DS10 42TPM024-11 240/1/50 Ducted 25,000 21,500 11.8 9.0 2.119 2.389 5,721 2,389 9.5 10.838CKPC30DS10 42TPM030-11 240/1/50 Ducted 33,000 28,500 12.0 9.0 2.750 3.167 7,425 3,167 12.0 13.838CKPC36DS10 42TPM036-11 240/1/50 Ducted 37,000 32,500 12.2 9.5 3.033 3.421 8,189 3,421 13.2 15.238CKPC36DS40 42TPM036-11 415/3/50 Ducted 37,000 32,500 12.2 9.5 3.033 3.421 8,189 3,421 5.0 5.738CKPS42DS40 42TPM042-11 415/3/50 Ducted 42,000 39,500 12.7 9.6 3.307 4.115 8,929 4,115 5.5 6.538CKPS48DS40 42TPM048-11 415/3/50 Ducted 47,500 43,000 12.2 9.0 3.893 4.778 10,511 4,778 6.6 7.838CKPS60DS40 42TPM060-11 415/3/50 Ducted 60,000 51,000 11.8 8.3 5.085 6.145 13,730 6,145 8.5 10.0Legend for Combination Matrix and RatingsCFM — Cubic Feet per MinuteEER — Energy Efficiency RatiokWh/Yr — kilowatt-hour/YearFANMin Max RLA LRA FLA38CKPC18DS10 207 253 6.2 48.0 0.52 8.3 1538CKPC24DS10 207 253 8.6 48.0 0.52 11.3 1538CKPC30DS10 207 253 11.4 64.0 1.50 15.8 2538CKPC36DS10 207 253 12.8 64.0 1.50 17.5 3038CKPC18DS70 207 253 6.2 48.0 0.52 8.3 1538CKPC24DS70 207 253 8.6 48.0 0.52 11.3 1538CKPC30DS70 207 253 11.4 64.0 1.50 15.8 2538CKPC36DS70 207 253 12.8 64.0 1.50 17.5 3038CKPC36DS40 360 440 4.5 35.0 0.80 6.4 1538CKPS42DS40 360 440 6.8 43.0 0.80 9.3 1538CKPS48DS40 360 440 7.1 52.0 0.80 9.7 1538CKPS60DS40 360 440 9.5 67.1 0.80 12.7 2038CKPC36DS90 360 440 4.5 35.0 0.80 6.4 1538CKPS42DS90 360 440 6.8 43.0 0.80 9.3 1538CKPS48DS90 360 440 7.1 52.0 0.80 9.7 1538CKPS60DS90 360 440 9.5 67.1 0.80 12.7 20Legend for Electrical Data TableEER (Btu/hr) / W Power Input (kW) AMPSOutdoor Model Indoor Model IndoorTypekWh/YrVoltage Capacity (Btu/hr)MCA — Minimum Circuit AmpsElectrical DataMOCP — Maximum Overcurrent ProtectionRLA — Rated Load AmpsLRA — Locked Rotor AmpsFLA — Full Load Amps400/3/50MCA MOCP240/1/50230/1/50415/3/50Annual Consumption @ T1 kWh/Year — 2,700 x T1Outdoor Model Power Supply(V/Ph/Hz)Voltage CompressorNotes: Testing as per ISO 13253 testing standard at T1 and T3 conditions.Annual Consumption @ T3 kWh/Year — 1,000 x T3Page 5