7Electrical dataUNIT SIZE-SERIES V/PHOPER VOLTS* COMPR FANFLA MCA60°CMINWIRESIZE†75°CMINWIRESIZE†MAXLENGTH(FT)60°/ 75°C‡MAXLENGTH(m)60°/ 75°C‡MAX FUSE**ORCKT BKR AMPSMax Min LRA RLA024-74, 75 230-1 253 207 72.5 15.0 0.6 19.4 14 14 39/37 9.9/9.4 30036-95400-3 440 36049.5 8.2 0.7 10.9 14 14 165/157 41.9/39.9 15048-95, 96 63.0 7.9 0.7 10.7 14 14 165/157 41.9/39.9 15060-95, 96 74.0 9.0 0.7 11.9 14 14 152/144 38.6/36.5 20FLA — Full Load AmpsLRA — Locked Rotor AmpsMCA — Minimum Circuit AmpsRLA — Rated Load AmpsPerformance summary* Tested CombinationNOTES:1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings forother combinations are determined under DOE computer simulation procedures.3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.Sound power (dBA) (A-WTG, Non Pure Tone Corrected)UNITSIZE INDOOR MODELNOMINAL AIRFLOWCOOLING CAP @ 95°F (35°C) COOLING CAP 115°F (46°C)Rated Capacity PowerkWRatedEERRated Capacity PowerkWCFM L/S BTUH kW BTUH kW024-74, 75 F(A,B)4(A,B)SF024* 800 380 23,000 6.7 2.34 10.30 20,700 6.1 2.87F(A,B)4(A,B)SF030 800 380 24,000 7.0 2.33 10.40 21,031 6.2 2.86FG3ASA024 800 380 23,000 6.7 2.40 9.70 20,023 5.9 2.95036-95 F(A,B)4(A,B)SF036* 1200 560 35,000 10.3 3.76 10.40 31,600 9.3 4.56F(A,B)4(A,B)S(F,B)042 1200 560 36,000 10.5 3.71 10.50 32,320 9.5 4.50FG3ASA036 1200 560 35,000 10.3 3.69 9.80 29,395 8.6 4.48048-95, 96F(A,B)4(A,B)S(F,B)048* 1600 750 47,000 13.8 5.12 9.50 42,400 12.4 6.20F(A,B)4(A,B)S(F,B)060 1600 750 48,000 14.1 5.26 9.50 43,540 12.8 6.37FG3ASA048 1600 750 46,000 13.5 5.20 9.10 41,100 12.0 6.30FG3ASA060 1600 750 47,000 13.8 5.25 9.20 42,179 12.4 6.35060-95, 96 F(A,B)4(A,B)S(F,B)060* 1850 950 57,500 16.8 6.03 9.50 52,100 15.3 7.26FB4(A,B)SB070 1850 950 59,000 17.3 6.14 9.50 53,364 15.6 7.39FG3ASA060 1850 950 56,500 16.6 6.00 9.40 51,286 15.0 7.23UNITSIZESOUNDRATING(dBA)A-WEIGHTED SOUND POWER LEVELS WITHIN OCTAVE BAND SHOWN (Hz)125 250 500 1000 2000 4000 8000024 72 53.5 63.0 65.0 67.0 63.5 59.0 50.5036 74 58.0 64.0 67.5 67.0 66.0 64.5 59.0048 75 55.5 63.0 66.5 68.0 68.0 65.0 59.5060 75 55.5 64.0 69.0 67.0 67.5 65.5 60.0* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70)Article 336-26.All motors/compressors contain internal overload protection.† American wire gage.‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.** Time-delay fuse.