Carrier 38VYM Series Installation Manual
38VYM R-410AGB - 4• Carefully recover refrigerant within this unit before final disposal orwhen servicing. Never vent refrigerant to atmosphere.Use approved recovery equipment for R-410A refrigerant.Do not use R-22 equipment.The unit must then be delivered to an appropriate disposal centeror to the original equipment dealer.• When lifting the unit, never use hooks inserted in the sidehandles, use special equipment (e.g. lifting devices, trolleys,etc.).Choosing the installation sitePositions to avoid:• Exposed to direct sun.• Too close to sources of heat radiation, vapour or flammable gas.• Particularly dusty areas.Recommendations:• Choose a position protected from opposing winds.• Choose a position sheltered from direct sun.• Choose an area where air outlet and unit noise will not botheryour neighbours.• Choose a position that allows for the clearances required.• Floor structure should be adequately strong to support unit weightand minimize vibration transmission.• Consider a position which will not obstruct passageways or doors.• For heat pump models, unit must be adequately raised abovefloor surface.• To drain the condensate water to a drain while operating inheating mode, insert the drain fitting into the hole underneath onthe left of the basin and use a vinyl pipe with a 16 mm internaldiameter. It must not be used at temperatures lower than 0°C.• If the unit is installed in areas where heavy snowfalls mayoccur, it is necessary to raise its level at least 200 mmabove the usual snow level or alternatively use the outdoorunit bracket kit.General informationUnit installationR-410A systems operate at higher pressures than standardR-22 systems. Do not use R-22 service equipment orcomponents on R-410A equipment.Read this instruction manual thoroughly before starting theinstallation.• This unit complies with low-voltage (EEC/73/23) and electro-magnetic compatibility (EEC/89/336) directives.• Check that the impedance of the mains power supply is inconformance with the unit power input indicated in theelectric data table III, on page 11 (EN 61000-3-11).• The installation must be carried out by a qualified installer.• Follow all current national safety code requirements. Inparticular ensure that a properly sized and connected groundwire is in place.• Check that voltage and frequency of the mains power supply arethose required; the available power must be adequate to operateany other possible appliances connected to the same line.Also ensure that national safety code requirements have beenfollowed for the mains supply circuit.• The mains supply must be connected to the outdoor unit.• Connect indoor and outdoor units with field-supplied copperpipes by means of flare connections. Use insulated seamlessrefrigeration grade pipe only, (Cu DHP type according toISO1337), degreased and deoxidized, suitable for operatingpressures of at least 4200 kPa and for burst pressure of atleast 20700 kPa. Under no circumstances must sanitary typecopper pipe be used.• After installation thoroughly test the system operation and explainall system functions to the owner.• Leave this manual with the owner for consultation during futureperiodic maintenance.• Use this unit only for factory approved applications: the unit issuitable for outdoor installation.• This installation manual describes the installation procedures ofthe outdoor unit of a residential split system consisting of unitsmanufactured by Carrier. Consult the Carrier stockist to check thepossibility of connecting your multisplit unit to indoor units otherthan those foreseen by the manufacturer. Do not connect this unitto any other manufacturer's indoor unit. Coupling units which havedifferent control systems, may cause irreversible damage and voidthe warranty protection. The manufacturer declines any liability forsystem malfunction resulting from unapproved coupling.IMPORTANT:During unit installation make first refrigerant connections andthen electrical connections. If the unit is uninstalled firstdisconnect electrical cables, then refrigerant connections.WARNING:Disconnect the mains power supply switch before servicingthe system or handling any internal parts of the unit.• The manufacturer declines any liability for damage resulting frommodifications or errors in the electrical or refrigerant connections.• Failure to observe the installation instructions or use of the unitunder conditions other than those indicated in Table II “Operatinglimits”, will immediately void the unit warranty.• Failure to observe electric safety codes may cause a fire hazard incase of short circuits.• Inspect equipment for damage due to improper transportation orhandling: file an immediate claim with the shipping company.Do not install or use damaged units.• In case of any malfunctioning turn the unit off, disconnect themains power supply and contact a qualified service engineer.• This equipment contains R-410A refrigerant, a substance thatdoes not deplete the ozone layer.• All manufacturing and packaging materials used for your newappliance are compatible with the environment and can berecycled.• Dispose of the packaging material in accordance with localrequirements. 100 mm min. mm gradient Gravel-filled trench.Snow Drain fitting Vinyl pipe |
Related manuals for Carrier 38VYM Series
Carrier 38VT 188CTST Series Installation Manual
Carrier Air-L Series Installation Manual
Carrier 42PHQ Series Installation Manual
Carrier Xpower Series Installation Manual
Carrier 42HQM Series Installation Manual
Carrier 42 DWC Series Installation Manual
Carrier 38QUS018DS2 Series Installation Manual
Carrier 38QUS014DS2 Series Installation Manual
Carrier 38QUS014DS2 series Installation Manual
Carrier 38QUS014DS2 Series Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine