40KMC---NGB - 3E N G L I S HTechnical dataNote: For power supply wire size and delay type fuses, refer to the outdoor unit installation instructions.Table I: Nominal dataPOWER INPUT (WATT)Cooling onlySizes standard Cooling Heating12 40KMC012-7N 75 7518 40KMC018-7N 80 8024 40KMC024-7N 105 10528 40KMC028-7N 107 10736 40KMC036-7N 131 13148 40KMC048-7N 178 17860 40KMC060-7N 231 231Sizes with electric heaters Cooling Heating12 40KMC112-7EN 75 157518 40KMC118-7EN 80 258024 40KMC124-7EN 105 260528 40KMC328-7EN 107 310736 40KMC336-7EN 131 313148 40KMC348-7EN 178 317860 40KMC360-7EN 231 3231POWER INPUT (WATT)Heat pumpSizes standard Cooling Heating12 40KMC012-7N 75 7518 40KMC018-7N 80 8024 40KMC024-7N 105 10528 40KMC028-7N 107 10736 40KMC036-7N 131 13148 40KMC048-7N 178 17860 40KMC060-7N 231 231Sizes with electric heaters Cooling Heating12 40KMC112-7EN 75 157518 40KMC118-7EN 80 158024 40KMC124-7EN 105 160528 40KMC328-7EN 107 210736 40KMC336-7EN 131 213148 40KMC348-7EN 178 217860 40KMC360-7EN 231 2231Table II: Technical data of electric heaters (if installed)Heat pump Cooling onlyMod. 12 18 24 28 36 48 60 12 18 24 28 36 48 60Electric heater kW 1.5 1.5 1.5 2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0 1.5 1.5 1.5 2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0+ + + + + +capacity 1.0 1.0 2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5Supply voltage V 230 230 230 230 230 230 230 230 230 230 400 400 400 400(*) (*) (*) (*) (*) (*) 3N 3N 3N 3NMax. current draw A 6.5 6.5 6.5 8.8 8.8 8.8 8.8 6,5 10.8 10.8 7.5 7.5 7.5 7.5Control device GMC electronic controlSafety thermostat N° 1 Manual reset thermostat ST1 60°CN° 1 Manual reset thermostat ST2 100°CPower supply cables mm 2 3 G 1.5 3 G 1.5 3 G 1.5 4 G 1.5 4 G 1.5 4 G 1.5 4 G 1.5 3 G 1.5 3 G 2.5 3 G 2.5 5 G 1.5 5 G 1.5 5 G 1.5 5 G 1.5Recommended fuse (gL type) A 8 8 8 8 8 8 8 8 12 12 10 10 10 10* In areas with a 2 kW limit for single-phase electric heaters it is possible to divide the power supply on two phases and neutral of a three phase supply with neutral.Use cable type H07 RN-F - 4G1,5 mm2 - 400V 2N ~Table III:Material suppliedDescription Quantity UseInstallation instructions 1 Indoor unit installationOwner's Manual 1 Correct useFresh air intake baffle 1 Air renewalTable IV: Operating limitsCooling / Heating Refer to outdoor unit installation manual.Nominal single-phase voltage 230V ~ 50Hz 230V-240V ~ 60HzMain power supply Operating voltage limits min. 198V – max. 264VNominal three-phase voltage 400V 3N~ 50HzOperating voltage limits min. 342V – max. 462VElectric heater 27°CTable V: Components required for a complete installationName SpecificationConnection pipe 40KMC 012N Ø (1/2") 12.70 mm (Gas) / Ø (1/4") 6.35 mm (Liquid)40KMC 018N, 024N, 028N, 036N, 048N and 060N Ø (1/2") 12.70 mm (Gas) / Ø (1/4") 6.35 mm (Liquid)Wall sleeveWall capFinishing tape PVC filmFastening tapeTube insulationDrain hose I.D. 16 - 17 mmSealer putty- Outdoor power supply cable H07 RN-F (60245IEC66),cable with synthetic rubber insulation and polychloroprene sheath.- Electrical connecting cable H07 RN-F (60245IEC66),between indoor and outdoor unit cable with synthetic rubber insulation and polychloroprenesheath.