12PERFORMANCE DATACOOLING CAPACITIESCOOLING ONLY 38HDF018 WITH 40KMC018Temp ° F (° C)Air EnteringCondenser(Edb)Air Entering Evaporator --- Cfm/BF330 / 0.04 400 / 0.04 450 / 0.04Air Entering Evaporator --- Ewb ° F (° C)57(13.9)62(16.7)67(19.4)72(22.2)57(13.9)62(16.7)67(19.4)72(22.2)57(13.9)62(16.7)67(19.4)72(22.2)55(12.8)TCG 16.1 17.3 18.2 19.4 17.0 17.9 19.3 20.3 17.6 18.5 19.7 20.8SHG 14.5 12.9 11.0 9.5 15.4 13.7 11.8 10.1 15.7 14.3 12.5 10.5TC 15.8 17.0 17.9 19.1 16.7 17.6 19.0 20.0 17.2 18.1 19.3 20.4kW 1.00 1.00 1.00 1.00 1.00 1.00 1.01 1.00 1.00 1.01 1.00 1.00CMP 0.79 0.79 0.79 0.79 0.77 0.77 0.78 0.76 0.75 0.75 0.74 0.75LDB 40.4 45.3 50.9 55.3 45.4 49.8 54.4 58.6 48.9 52.1 56.0 60.3LWB 36.6 42.2 48.5 54.4 39.7 45.7 51.2 57.3 41.4 47.3 53.0 58.965(18.3)TCG 15.6 17.0 18.0 19.4 16.8 17.8 19.1 20.3 16.8 18.1 19.6 20.8SHG 14.3 12.9 10.9 9.4 15.7 13.9 11.8 10.0 16.8 14.3 12.4 10.4TC 15.3 16.7 17.8 19.1 16.4 17.4 18.7 19.9 16.4 17.7 19.2 20.4kW 1.11 1.12 1.13 1.12 1.12 1.12 1.13 1.12 1.12 1.13 1.13 1.12CMP 0.90 0.91 0.92 0.91 0.89 0.89 0.89 0.89 0.86 0.87 0.87 0.87LDB 40.9 45.2 51.2 55.7 44.9 49.3 54.3 58.8 46.6 52.0 56.2 60.5LWB 37.4 42.7 48.7 54.5 40.0 45.8 51.5 57.4 42.2 47.6 53.1 58.975(23.9)TCG 15.1 16.5 17.6 19.1 15.8 17.3 18.6 20.0 16.5 17.8 19.1 20.5SHG 14.0 12.8 10.8 9.2 15.8 13.9 11.8 9.9 16.5 14.6 12.3 10.3TC 14.8 16.2 17.4 18.9 15.4 17.0 18.3 19.6 16.1 17.4 18.7 20.0kW 1.24 1.25 1.26 1.26 1.25 1.26 1.26 1.26 1.25 1.26 1.26 1.25CMP 1.03 1.04 1.05 1.05 1.01 1.02 1.02 1.02 1.00 1.00 1.00 1.00LDB 41.8 45.5 51.4 56.1 44.6 49.3 54.4 58.9 47.3 51.3 56.3 60.6LWB 38.2 43.4 49.2 54.8 41.2 46.3 51.9 57.6 42.6 47.9 53.5 59.185(29.4)TCG 14.1 15.7 17.2 18.6 15.3 16.6 18.0 19.4 16.0 17.1 18.5 19.9SHG 14.0 12.5 10.8 9.0 15.3 13.8 11.6 9.7 16.0 14.5 12.2 10.1TC 13.9 15.5 16.9 18.3 14.9 16.3 17.6 19.1 15.6 16.7 18.0 19.5kW 1.38 1.40 1.40 1.41 1.39 1.40 1.40 1.40 1.40 1.40 1.40 1.41CMP 1.17 1.19 1.19 1.20 1.15 1.17 1.17 1.17 1.14 1.15 1.15 1.15LDB 41.7 46.3 51.5 56.6 45.8 49.5 54.8 59.4 48.3 51.5 56.5 61.0LWB 39.6 44.3 49.7 55.4 41.8 47.0 52.5 58.1 43.1 48.5 54.0 59.695(35.0)TCG 13.4 14.8 16.4 17.9 14.6 15.7 17.1 18.7 15.3 16.3 17.4 19.1SHG 13.4 12.1 10.5 8.8 14.6 13.4 11.3 9.5 15.3 14.2 11.8 9.8TC 13.1 14.6 16.1 17.6 14.2 15.4 16.8 18.3 14.9 15.9 17.0 18.7kW 1.53 1.55 1.56 1.57 1.54 1.56 1.57 1.57 1.55 1.56 1.56 1.57CMP 1.32 1.34 1.35 1.36 1.31 1.32 1.33 1.33 1.30 1.31 1.31 1.31LDB 43.5 47.4 52.1 57.2 47.3 50.3 55.4 59.9 49.7 52.0 57.0 61.6LWB 40.6 45.5 50.6 56.1 42.6 48.0 53.3 58.7 43.7 49.3 54.7 60.1105(40.6)TCG 12.6 13.8 15.5 16.9 13.8 14.7 16.2 17.7 14.5 15.5 16.7 18.1SHG 12.6 11.6 10.1 8.4 13.8 12.9 11.0 9.1 14.5 13.2 11.7 9.5TC 12.4 13.5 15.2 16.7 13.5 14.3 15.9 17.4 14.1 15.1 16.3 17.7kW 1.69 1.71 1.74 1.74 1.71 1.72 1.74 1.74 1.72 1.73 1.74 1.74CMP 1.48 1.50 1.53 1.53 1.47 1.49 1.51 1.51 1.46 1.48 1.49 1.49LDB 45.6 48.8 53.1 58.2 49.1 51.5 56.0 60.8 51.3 54.1 57.5 62.3LWB 41.7 46.9 51.7 57.1 43.5 49.1 54.2 59.5 44.5 50.0 55.4 60.8115(46.1)TCG 11.8 12.6 14.3 15.9 12.9 13.7 15.1 16.7 13.6 14.2 15.5 17.1SHG 11.8 11.0 9.6 8.0 12.9 11.9 10.7 8.7 13.6 12.8 11.3 9.1TC 11.5 12.4 14.1 15.6 12.6 13.4 14.8 16.3 13.2 13.7 15.1 16.7kW 1.87 1.88 1.91 1.93 1.88 1.89 1.93 1.93 1.90 1.91 1.93 1.93CMP 1.66 1.67 1.70 1.72 1.65 1.66 1.69 1.70 1.64 1.65 1.67 1.68LDB 48.0 50.4 54.5 59.3 51.2 53.7 56.8 61.6 53.1 55.0 58.3 62.9LWB 42.9 48.4 53.1 58.2 44.5 50.1 55.2 60.4 45.4 51.2 56.4 61.6125(51.7)TCG 10.9 11.6 13.0 14.7 11.9 12.0 13.7 15.3 12.6 12.6 14.2 15.7SHG 10.9 10.1 9.1 7.6 11.9 11.8 10.1 8.2 12.6 12.6 10.8 8.6TC 10.6 11.4 12.8 14.5 11.6 11.7 13.4 15.0 12.2 12.2 13.7 15.3kW 2.06 2.06 2.10 2.13 2.07 2.07 2.12 2.13 2.09 2.09 2.13 2.13CMP 1.85 1.85 1.89 1.92 1.84 1.84 1.88 1.90 1.83 1.83 1.87 1.88LDB 50.5 52.9 55.9 60.4 53.5 54.0 58.0 62.7 55.2 55.3 59.2 63.9LWB 44.1 49.6 54.5 59.4 45.6 51.7 56.4 61.4 46.4 52.3 57.4 62.5Rating conditionNot recommended for long---term operation.LEGENDBF --- Bypass FactorCMP --- CompressorEdb --- Entering Dry BulbEwb --- Entering Wet BulbkW --- Total PowerLDB --- Leaving Dry BulbLWB --- Leaving Wet BulbSHG --- Gross Sensible Capacity (1000 Btu/hour)TC --- Total Net Cooling Capacity (1000 Btu/hour)TCG --- Gross Cooling Capacity (1000 Btu/hour)NOTES:1. Direct interpolation is permissible. Do not extrapolate.2. The SHG is based on 80_F (26.67_C) edb temperature of airentering indoor coil.Below 80_F (26.67_C) edb, subtract (corr factor x cfm) fromSHG.Above 80_F (26.67_C) edb, add (corr factor x cfm) to SHG.Correction Factor = 1.10 x (1 --- BF) x (edb --- 80).40KMC, KMQ / 38HDF, QRF